A comparison between 915 MHz and 2450 MHz microwave ablation systems for the treatment of small diameter lung metastases.
نویسندگان
چکیده
PURPOSE We aimed to retrospectively compare the local tumor control rates between low frequency (LF) and high frequency (HF) microwave ablation devices in the treatment of <3 cm lung metastases. METHODS A total of 36 patients (55 tumors) were treated with the LF system (915 MHz) and 30 patients (39 tumors) were treated with the HF system (2450 MHz) between January 2011 and March 2016. Computed tomography (CT) scans performed prior to and 24 hours after the ablation were used to measure the size of the ablation zone and to calculate the ablation margin. The subsequent CTs were used to detect local tumor progression. Possible predictive factors for local progression were analyzed. All patients had a minimum follow-up of 3 months with a median of 13.8 months for the LF group and 11.7 months for the HF group. RESULTS The ablation margin (P = 0.015), blood vessel proximity (P = 0.006), and colorectal origin (P = 0.029) were significantly associated with the local progression rate. The local progression rates were 36.3% for LF ablations and 12.8% for HF ablations. The 6, 12, and 18 months local progression-free survival rates were 79%, 65.2% and 53% for the LF group and 97.1%, 93.7%, and 58.4% for the HF group, with a significant difference between the survival curves (P = 0.048). CONCLUSION HF ablations resulted in larger ablation margins with fewer local progression compared with LF ablations.
منابع مشابه
Laboratory of Environmental Biophysics: Summary Statement
The objectives of the nonionizing radiation research program are as follows: (1) to develop microwave exposure systems for bioeffects research; (2) to develop and test techniques for measuring microwave energy absorption; (3) to determine the effect of microwaves on isolated nerve preparations; (4) to determine how 2450 MHz microwave radiation interacts with biological systems at all levels; (5...
متن کاملMicrowave Radiation—Therapeutic Application for Cure of Liver Tumor
The electromagnetic fields have a great influence on the behaviour of all the living systems. Microwaves occupy range in the EM spectrum is between frequencies of 300 MHz to 300 GHz with wavelengths of approximately 1 m to 1 mm. From several decades, hyperthermia has become major subject of interest in investigating the biological effects and applications of microwaves. Therapeutic applications...
متن کاملMicrowave catheter ablation of myocardium in vitro. Assessment of the characteristics of tissue heating and injury.
BACKGROUND Radiofrequency (RF) catheter ablation lesion size has been limited by the small volume of tissue directly heated by the RF electrode. Microwave (MW) energy has been proposed as an alternative energy source to generate larger lesions because of its increased volume of direct tissue heating. To further characterize MW ablation of myocardium, we studied the temperature-versus-distance p...
متن کاملEffect of Dielectric Properties of a Solvent-Water Mixture Used in Microwave-Assisted Extraction of Antioxidants from Potato Peels
The dielectric properties of a methanol-water mixture were measured at different temperatures from 20 to 80 °C at two frequencies 915 MHz and 2450 MHz. These frequencies are most commonly used on industrial and domestic scales respectively. In this study, the dielectric properties of a methanol-water mixture were found to be dependent on temperature, solvent concentration, and presence of plant...
متن کاملDevelopment and Analysis of a Microwave Direct Contact Water-loaded Box-horn Applicator for Therapeutic Heating of Bio-medium
A novel, potential and efficient microwave direct contact hyperthermia applicator referred to as water-loaded box-horn for therapeutic heating of bio-medium is designed and developed at 915 and 2450 MHz. Also, theoretical expressions for fields in bio-medium as produced by a direct contact box-horn applicator have been derived using plane wave spectral technique. The box-horn is a special type ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Diagnostic and interventional radiology
دوره 24 1 شماره
صفحات -
تاریخ انتشار 2018