Investigation of differences between nanosecond electropulse and electrohydraulic methods of lithotripsy: a comparative in vitro study of efficacy.
نویسندگان
چکیده
PURPOSE To compare the effectiveness of novel nanosecond electropulse lithotripsy with standard electrohydraulic lithotripsy to demonstrate and authenticate their differences because both modalities appear to be similar. MATERIALS AND METHODS An in vitro fragmentation study was conducted using cuboid BegoStone phantoms, which mimic hard and soft stones, based on an established model. Three different stone sizes were used in the testing having volumes of 100, 256, and 320 mm(3). A nanosecond electropulse lithotripter (NEPL) and an electrohydraulic lithotripter (EHL) were operated using a range of probe sizes at comparable energy settings and pulse rates with the objective of obtaining a stone fragment <2 mm. To compare the efficacy of these two lithotripters, the number of pulses needed for stone phantom fragmentation was recorded according to probe size and energy setting, which were then converted into units of cumulative energy. RESULTS The results clearly demonstrated that, for all operating modes and stone phantom types, the NEPL device needs much less cumulative energy and thus fewer pulses and consequently less time to achieve stone fragmentation than the EHL device. The disparity in the results is explained by the dissimilar mechanisms at work in the compared lithotripters during destruction of the stone. The electropulse stone disintegration mechanism transfers energy directly into the stone because of discharge penetration into a solid body. This contrasts with the electrohydraulic mechanism in EHL in which energy is transferred through the liquid medium, which also creates a damaging shockwave. CONCLUSIONS The findings demonstrate that, for all operating modes and stone types, the NEPL device needs much less cumulative energy and thus fewer pulses for stone fragmentation than the EHL device. The disparity in the results is explained by the dissimilar mechanisms at work in the compared lithotripters during destruction of the stone.
منابع مشابه
Comparative in vitro study of the effectiveness of nanosecond electrical pulse and laser lithotripters.
A comparative in vitro research of the efficiency of nanosecond electropulse (Urolit-105M) and Holmium laser (Auriga) lithotripters is presented in this work. Four sizes of BegoStone cement stones of various densities were fabricated for these tests. A comparison of the efficiency of the lithotripters was performed in the experiments on pairs of probes corresponding to a predetermined stone siz...
متن کاملRetrograde endoscopic lithotripsy using the innovative nanosecond electropulse method
PURPOSE The purpose of this clinical study is to assess the safety and efficiency of a novel lithotripsy method for endoscopic treatment of urinary stones throughout the urinary tract via semi-rigid and flexible endoscopes. This new method is based on the transfer of nanosecond high voltage electric pulses to the stones through flexible probes of various sizes. METHODS The study involved 879 ...
متن کاملElectrohydraulic lithotripsy of gall stones--in vitro and animal studies.
Electrohydraulic lithotripsy of human gall stones was investigated in vitro in a bath of saline and in a saline perfused bile duct. The technique was effective--only two stones could not be shattered. Electrohydraulic lithotripsy power requirement correlated with mechanical strength of stones, but not with biochemical composition. A trend toward higher power requirement was recorded with larger...
متن کاملElectrohydraulic lithotripsy with peroral choledochoscopy.
OBJECTIVE To determine the efficacy of peroral electrohydraulic lithotripsy performed with an extra large duodenoscope (outside diameter 14.8 mm) and a choledochoscope with a diameter of 4.1 mm (Olympus "mother and baby" endoscope system) in the removal of very large stones from the common bile duct. DESIGN Prospective study of patients with giant stones in the common bile duct that were resi...
متن کاملRadioprotective efficacy of prunus avium fruit in mice brain with reference to in-vitro and in-vivo studies
Background: Radioprotective efficacy of Prunus avium fruit extract (PAE) rich in vitamin A, C, E and anthocyanin was studied against radiation induced biochemical alterations in mice brain. Materials and Methods: In-vitro assays were performed with PAE for its antioxidant studies thereafter for in-vivo study, Swiss albino mice were divided into five groups. Group 1 (control) normal mice. Group ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of endourology
دوره 28 4 شماره
صفحات -
تاریخ انتشار 2014