Endovascular catheter for magnetic navigation under MR imaging guidance: evaluation of safety in vivo at 1.5T.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Endovascular navigation under MR imaging guidance can be facilitated by a catheter with steerable microcoils on the tip. Not only do microcoils create visible artifacts allowing catheter tracking, but also they create a small magnetic moment permitting remote-controlled catheter tip deflection. A side product of catheter tip electrical currents, however, is the heat that might damage blood vessels. We sought to determine the upper boundary of electrical currents safely usable at 1.5T in a coil-tipped microcatheter system. MATERIALS AND METHODS Alumina tubes with solenoid copper coils were attached to neurovascular microcatheters with heat shrink-wrap. Catheters were tested in carotid arteries of 8 pigs. The catheters were advanced under x-ray fluoroscopy and MR imaging. Currents from 0 mA to 700 mA were applied to test heating and potential vascular damage. Postmortem histologic analysis was the primary endpoint. RESULTS Several heat-mitigation strategies demonstrated negligible vascular damage compared with control arteries. Coil currents ≤300 mA resulted in no damage (0/58 samples) compared with 9 (25%) of 36 samples for > 300-mA activations (P = .0001). Tip coil activation ≤1 minute and a proximal carotid guide catheter saline drip > 2 mL/minute also had a nonsignificantly lower likelihood of vascular damage. For catheter tip coil activations ≤300 mA for ≤1 minute in normal carotid flow, 0 of 43 samples had tissue damage. CONCLUSIONS Activations of copper coils at the tip of microcatheters at low currents in 1.5T MR scanners can be achieved without significant damage to blood vessel walls in a controlled experimental setting. Further optimization of catheter design and procedure protocols is necessary for safe remote control magnetic catheter guidance.
منابع مشابه
Remote control catheter navigation: options for guidance under MRI
BACKGROUND Image-guided endovascular interventions have gained increasing popularity in clinical practice, and magnetic resonance imaging (MRI) is emerging as an attractive alternative to X-ray fluoroscopy for guiding such interventions. Steering catheters by remote control under MRI guidance offers unique challenges and opportunities. METHODS In this review, the benefits and limitations of M...
متن کاملIn-vitro evaluation of a novel MR-compatible cardiac bioptome catheter for MR-guided myocardial biopsies
Background Retrieval of myocardial biopsies under X-ray guidance in patients with unclear myocardial dysfunction or acute myocarditis is a difficult and potentially hazardous procedure since soft tissues only offer low X-ray contrast during the procedure and extraction of biopsies could cause myocardial rupture and concomitant haemopericardium. In contrast, cardiac magnetic resonance imaging pr...
متن کاملPair of resonant fiducial markers for localization of endovascular catheters at all catheter orientations.
PURPOSE To test wireless resonance circuits (RC) to be used as fiducial marker of endovascular catheters during MR-guided interventions. Current markers loose their signal enhancement for certain catheter orientations. The purpose of this study was to test a marker setup which overcomes this orientation problem. MATERIALS AND METHODS The markers were constructed from a pair of two RCs. The RC...
متن کاملMR imaging-guided intravascular procedures: initial demonstration in a pig model.
With use of an open 1.5-T magnetic resonance (MR) imager and a tracking catheter, the authors successfully placed the catheter into the left or right sacral artery in pigs. The tracking catheter comprised a 5.3-F percutaneous transluminal angioplasty catheter with a small copper radio-frequency coil in its tip. With use of the coil as an antenna, the catheter tip position was projected in real ...
متن کاملPreclinical Evaluation of an MR-EP Suite including an MR-EP Navigator and Dedicated MR-EP Catheters
Introduction: Cardiac arrhythmias, e.g. atrial fibrillation and ventricular tachycardia, are increasingly treated by electrophysiological (EP) interventions [1]. Applying MR for guiding these interventions offers advantages like 3D visualization of the cardiac soft tissue in relation to the catheter, visualization of the treatment effect and absence of ionizing radiation [2,3]. The step towards...