Comprehensive Three-Dimensional Analysis of the Neuroretinal Rim in Glaucoma Using High-Density Spectral-Domain Optical Coherence Tomography Volume Scans
نویسندگان
چکیده
Purpose To describe spectral-domain optical coherence tomography (OCT) methods for quantifying neuroretinal rim tissue in glaucoma and to compare these methods to the traditional retinal nerve fiber layer thickness diagnostic parameter. Methods Neuroretinal rim parameters derived from three-dimensional (3D) volume scans were compared with the two-dimensional (2D) Spectralis retinal nerve fiber layer (RNFL) thickness scans for diagnostic capability. This study analyzed one eye per patient of 104 glaucoma patients and 58 healthy subjects. The shortest distances between the cup surface and the OCT-based disc margin were automatically calculated to determine the thickness and area of the minimum distance band (MDB) neuroretinal rim parameter. Traditional 150-μm reference surface-based rim parameters (volume, area, and thickness) were also calculated. The diagnostic capabilities of these five parameters were compared with RNFL thickness using the area under the receiver operating characteristic (AUROC) curves. Results The MDB thickness had significantly higher diagnostic capability than the RNFL thickness in the nasal (0.913 vs. 0.818, P = 0.004) and temporal (0.922 vs. 0.858, P = 0.026) quadrants and the inferonasal (0.950 vs. 0.897, P = 0.011) and superonasal (0.933 vs. 0.868, P = 0.012) sectors. The MDB area and the three neuroretinal rim parameters based on the 150-μm reference surface had diagnostic capabilities similar to RNFL thickness. Conclusions The 3D MDB thickness had a high diagnostic capability for glaucoma and may be of significant clinical utility. It had higher diagnostic capability than the RNFL thickness in the nasal and temporal quadrants and the inferonasal and superonasal sectors.
منابع مشابه
Diagnostic Performance of a Novel Three-Dimensional Neuroretinal Rim Parameter for Glaucoma Using High-Density Volume Scans.
PURPOSE To evaluate the diagnostic performance of a 3-dimensional (3D) neuroretinal rim parameter, the minimum distance band (MDB), using optical coherence tomography (OCT) high-density volume scans for open-angle glaucoma. DESIGN Reliability analysis. METHODS setting: Institutional. STUDY POPULATION Total of 163 patients (105 glaucoma and 58 healthy subjects). OBSERVATION PROCEDURES On...
متن کاملA method to estimate the amount of neuroretinal rim tissue in glaucoma: comparison with current methods for measuring rim area.
PURPOSE To test whether the minimum rim area assessed by spectral domain optical coherence tomography (SD-OCT), based on the shortest distance from the Bruch membrane opening (BMO) to the inner limiting membrane, corresponds more closely to retinal nerve fiber layer (RNFL) thickness and visual field mean deviation (MD) than current rim measures in early glaucoma. DESIGN Prospective cross-sect...
متن کاملStructure-Function Relationship Between Bruch's Membrane Opening-Based Optic Nerve Head Parameters and Visual Field Defects in Glaucoma.
PURPOSE This study was performed to evaluate the structure-function relationship between Bruch's membrane opening (BMO) parameters of the optic nerve head (ONH) and visual field (VF) sensitivity. METHODS Forty-six right eyes of 46 patients with open-angle glaucoma (OAG) in the patient group and 12 right eyes in the control group were included. Standard automated perimetry (SAP) and spectral-d...
متن کاملOptic nerve head topographic measurements and retinal nerve fiber layer thickness in physiologic large cups.
PURPOSE To evaluate the parameters of optic nerve head (ONH) and retinal nerve fiber layer (RNFL) in patients with large cup/disc ratio (CDR) and normal neuroretinal rim configuration who have normal perimetry (physiologic large cups, LC) and to compare these parameters with those of the normal and early glaucoma patients. METHODS Using Heidelberg retinal tomography (HRT) and optical coherenc...
متن کاملبررسی پایایی و تکرار پذیری دستگاه Spectral domain optical coherence tomography در اندازه گیری ضخامت ماکولا در چشمهای طبیعی قبل و بعد از گشاد کردن مردمک
Background: optical coherence tomography is one of the most valuable imaging techniques in the evaluation of macula. Objective: to investigate the repeatability and reproducibility of OCT in measuring the macular thickness in normal eyes before and after pupil dilation. Methods: A total of 44 eyes were enrolled. All subjects underwent macular thickness measurement using the Cirrus SD-OCT ma...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 57 شماره
صفحات -
تاریخ انتشار 2016