Radioimmunoassay of serotonin (5-hydroxytryptamine) in cerebrospinal fluid, plasma, and serum.

نویسندگان

  • F Engbaek
  • B Voldby
چکیده

We describe a direct radioimmunoassay for serotonin (5-hydroxytryptamine) in cerebrospinal fluid, platelet-poor plasma, and serum. We raised antisera in rabbits against serotonin diazotized to a conjugate of bovine albumin and D,L-p-aminophenylalanine. Polyethylene glycol, alone or in combination with anti-rabbit immunoglobulins, is used to separate bound and unbound tritiated serotonin. The minimum concentration of serotonin detectable is 2 nmol/L in a 200-microL sample. Within-day precision (CV) is 4.3%, between-day precision 7.7%. Analytical recoveries of serotonin are 109% and 101% for cerebrospinal fluid and plasma, respectively. Tryptophan, 5-hydroxytryptophan, 5-hydroxyindoleacetic acid, and 5-hydroxytryptophol do not interfere with the assay. However, 5-methoxytryptamine and tryptamine cross react. Of samples of cerebrospinal fluid from patients with disc herniations (n = 21) or low-pressure hydrocephalus (n = 10), one-third had concentrations of 2-4 nmol/L and two-thirds were below the minimum detectable concentration. The observed range for the concentration of serotonin in plasma of 14 normal subjects was 5-14 nmol/L (mean +/- SD, 9 +/- 3 nmol/L). The observed ranges for serotonin in serum were: for 10 women 520-900 (mean +/- SD: 695 +/- 110) nmol/L and for 10 men 380-680 (520 +/- 94) nmol/L.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Human a , - microglobulin levels in various body fluids

a,-Microglobulin levels in serum and urine were estimated by using single radial immunodiffusion, resulting in the following mean values: umbilical cord blood serum, 40*6 mg/I; normal adult serum, 44-2 mg/I; and normal urine, 5 7 mg/24 h urine volume. Slightly higher levels of serum a1-microglobulin were found in infants and the aged. Serum and urine a,-microglobulin levels in patients with ren...

متن کامل

Is there any Correlation between Cerebrospinal Fluid and Serum C-reactive Protein in Neonates Suspected to Meningitis?

Background: Meningitis is a common life threatening infection in neonatal period. Diagnostic value of CSF-CRP level in bacterial meningitis in children and adults has been studied worldwide, but there are limited studies on CSF-CRP in neonatal meningitis. This study conducted to assess any relation between CSF-CRP and plasma CRP levels and abnormal CSF findings in neonates suspected to meningit...

متن کامل

Tryptophan, 5-hydroxyindoleacetic acid and indoleacetic acid in human cerebrospinal fluid: interrelationships and the influence of age, sex, epilepsy and anticonvulsant drugs.

Tryptophan, 5-hydroxyindoleacetic acid and indoleacetic acid were measured in cerebrospinal fluid, taken during pneumoencephalography, from a large series of patients, the majority of whom were epileptics, most of them receiving anticonvulsants. CSF indoleacetic acid reflects CNS tyrptamine metabolism in the same way that CSF 5-hydroxyindoleacetic acid reflects CNS 5-hydroxytryptamine metabolis...

متن کامل

Serotonergic dysfunction and aggression control

In the early seventies we reported the occurrence of diminished post-probenecid accumulation of 5hydroxyindoleacetic acid (5-HIAA) in cerebrospinal fluid (CSF) in depression (van Praag el al. 1970; van Praag & Korf, 1971). Lowered baseline and post-probenecid 5-HIAA levels in CSF are an indication of diminished metabolism of the mother amine serotonin (5-hydroxytryptamine, 5HT) in the CNS. Low ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 28 4 Pt 1  شماره 

صفحات  -

تاریخ انتشار 1982