British randomised controlled trial of AV and VV optimization (“BRAVO”) study: rationale, design, and endpoints
نویسندگان
چکیده
BACKGROUND Echocardiographic optimization of pacemaker settings is the current standard of care for patients treated with cardiac resynchronization therapy. However, the process requires considerable time of expert staff. The BRAVO study is a non-inferiority trial comparing echocardiographic optimization of atrioventricular (AV) and interventricular (VV) delay with an alternative method using non-invasive blood pressure monitoring that can be automated to consume less staff resources. METHODS/DESIGN BRAVO is a multi-centre, randomized, cross-over, non-inferiority trial of 400 patients with a previously implanted cardiac resynchronization device. Patients are randomly allocated to six months in each arm. In the echocardiographic arm, AV delay is optimized using the iterative method and VV delay by maximizing LVOT VTI. In the haemodynamic arm AV and VV delay are optimized using non-invasive blood pressure measured using finger photoplethysmography. At the end of each six month arm, patients undergo the primary outcome measure of objective exercise capacity, quantified as peak oxygen uptake (VO2) on a cardiopulmonary exercise test. Secondary outcome measures are echocardiographic measurement of left ventricular remodelling, quality of life score and N-terminal pro B-type Natriuretic Peptide (NT-pro BNP). The study is scheduled to complete recruitment in December 2013 and to complete follow up in December 2014. DISCUSSION If exercise capacity is non-inferior with haemodynamic optimization compared with echocardiographic optimization, it would be proof of concept that haemodynamic optimization is an acceptable alternative which has the potential to be more easily implemented. TRIAL REGISTRATION Clinicaltrials.gov NCT01258829.
منابع مشابه
Contractility sensor-guided optimization of cardiac resynchronization therapy: results from the RESPOND-CRT trial
Aims Although cardiac resynchronization therapy (CRT) is effective in patients with systolic heart failure (HF) and a wide QRS interval, a substantial proportion of patients remain non-responsive. The SonR contractility sensor embedded in the right atrial lead enables individualized automatic optimization of the atrioventricular (AV) and interventricular (VV) timings. The RESPOND-CRT study inve...
متن کاملP-78: A Randomised Placebo-Controlled Trial to Determine the Effect of Iron Supplementation on Neonatal Outcome in Pregnant Women with Normal Heamoglobin (Hb=11-13
Background: To study the effect of iran supplementation on neonal outcom in pregnant women with normal heamoglobin (Hb=11g/dl )13 g/dl Methods : two handrad pregnant women with Hb=11-13 g/dl in the early slage of pregmancy? Materials and Methods: Each woman look one tablet of 50 mg of ferrossalphate daily in the case group (n=100) and placebo group (n=100). Results: While no significant differe...
متن کاملCardiac resynchronization therapy: mechanisms of action and scope for further improvement in cardiac function
Aims Cardiac resynchronization therapy (CRT) may exert its beneficial haemodynamic effect by improving ventricular synchrony and improving atrioventricular (AV) timing. The aim of this study was to establish the relative importance of the mechanisms through which CRT improves cardiac function and explore the potential for additional improvements with improved ventricular resynchronization. Me...
متن کاملWhether noninvasive optimization of AV and VV delays improves the response to cardiac resynchronization therapy.
BACKGROUND Device optimization is not routinely performed in patients who underwent cardiac resynchronization therapy (CRT) device implantation. Noninvasive optimization of CRT devices by measurement of cardiac output (CO) can be used as a simple method to assess ventricular systolic performance. The aim of this study was to assess whether optimization of atrioventricular (AV) and interventricu...
متن کاملAuthor's response to reviews Title: Rationale and design of the balANZ trial: A randomised controlled trial of low GDP, neutral pH versus standard peritoneal dialysis solution for the preservation of residual renal function Authors:
Title: Rationale and design of the balANZ trial: A randomised controlled trial of low GDP, neutral pH versus standard peritoneal dialysis solution for the preservation of residual renal function
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 14 شماره
صفحات -