Influence of pH-neutral peritoneal dialysis solution.

نویسندگان

  • Misaki Moriishi
  • Hideki Kawanishi
  • Tooru Kawai
  • Syunsake Takahashi
  • Takayuki Hirai
  • Masayaki Shishida
  • Hiroshi Watanabe
  • Naoko Takahashi
چکیده

We evaluated the influence of a neutral peritoneal dialysis solution (PDS) on the peritoneum. The subjects were 10 stable PD patients using conventional PDS. We substituted pH-neutral PDS (PD Solita A: Shimizu Medical, Tokyo, Japan) for conventional PDS (Gambrosol A: Shimizu Medical). Effluent from 4-hour dwells was collected, and the appearance rate of cancer antigen 125 (CA125-AR) was calculated using the method of Pannekeet et al and corrected to body surface area. The dialysate-to-plasma creatinine (D/P Cr) was obtained, and personal dialysis capacity (PDC) was evaluated at 3-month intervals. Mean daily ultrafiltration volumes did not significantly change when pH-neutral PDS was used. The mean CA125-AR obtained 1 month after substitution was twice as high as that before substitution (139.2 +/- 47.3 U/min/1.73 m2 before substitution vs. 286 +/- 126.2 U/min/1.73 m2 1 month later). However, mean values of CA125-AR were maintained at higher levels and did not significantly vary for 7 months after PD fluid substitution. When the change in CA125-AR (delta CA125-AR) was calculated as the ratio of the CA125-AR value before substitution to that after substitution at the respective measurement points, delta CA125-AR negatively correlated with D/P Cr. However, none of % area, % absorption, or % plasma loss significantly correlated with the delta CA125-AR obtained 6 months later. Although mesothelial cell viability may increase with the use of pH-neutral PDS, the level of the increase may differ depending on the severity of peritoneal damage. In addition, the use of a neutral PD fluid did not improve the endothelial cell system. In the future, development of a novel osmotic pressure-regulating substance substituting for glucose is essential to the development of PD fluids with higher biocompatibility.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New pH-neutral peritoneal dialysis solution, low in glucose degradation products, in a double-chamber bag.

Fresenius Medical Care-North America has developed a neutral-pH version of its Delflex peritoneal dialysis (PD) solution with low glucose degradation products (GDPs): Delflex Neutral pH. The Delflex Neutral pH system stores the PD solution in a dual-chamber bag. The product is admixed by the patient before use. The new design facilitates GDP reduction in two ways. First, GDPs are reduced becaus...

متن کامل

Author's response to reviews Title: Rationale and design of the balANZ trial: A randomised controlled trial of low GDP, neutral pH versus standard peritoneal dialysis solution for the preservation of residual renal function Authors:

Title: Rationale and design of the balANZ trial: A randomised controlled trial of low GDP, neutral pH versus standard peritoneal dialysis solution for the preservation of residual renal function

متن کامل

Effect of standard and neutral-pH peritoneal dialysis solutions upon fibroblasts proliferation.

INTRODUCTION Continuous exposition of the peritoneal membrane to conventional dialysis solutions is an important risk factor for inducing structural and functional alterations. OBJECTIVE To compare in vitro mouse fibroblast NIH-3T3 cell viability after exposition to a neutral pH dialysis solution in comparison to cells exposed to a standard solution. METHODS Experimental study to compare th...

متن کامل

Increased peritoneal permeability at peritoneal dialysis initiation is a potential cardiovascular risk in patients using biocompatible peritoneal dialysis solution

BACKGROUND Cardiovascular disease is a frequent cause of death in peritoneal dialysis patients. Biocompatible peritoneal dialysis solutions with neutral pH have been anticipated to reduce cardiovascular disease more than conventional peritoneal dialysis solutions with low pH, but it remains unclear which factors at peritoneal dialysis initiation increase cardiovascular risk in patients using bi...

متن کامل

Free water transport in children on peritoneal dialysis is higher with more biocompatible dialysis solutions, higher with older age and declines with time.

BACKGROUND Water transport in peritoneal dialysis occurs through small pores and aquaporins. Free water transport (FWT) occurs through aquaporins only and gives a reflection of peritoneal aquaporin function. In this study, FWT in children was calculated for the first time in different settings. METHODS A prospective cohort study was performed; 87 peritoneal equilibrium tests (PETs) were analy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Advances in peritoneal dialysis. Conference on Peritoneal Dialysis

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2002