Validation of a spectral light scattering method to differentiate large from small particles in intraocular lenses.

نویسندگان

  • Grzegorz Łabuz
  • Eleni Papadatou
  • Fernando Vargas-Martín
  • Norberto López-Gil
  • Nicolaas J Reus
  • Thomas J T P van den Berg
چکیده

A psychophysical approach has been designed to measure straylight from intraocular lenses (IOLs) in vitro. This approach uses a clinical straylight meter (C-Quant) and an observer's eye as optical detector. Based on this, we introduced a method for study of straylight-wavelength dependency for IOLs. This dependency can be used to distinguish between 2 types of scattering particles (small and large) as defined by Mie theory. Validation was performed using a turbidity standard and scattering filters. Several IOLs were analyzed to identify potential scattering sources. Large particles were found to predominate in scattering from the studied lenses. This was confirmed by straylight-angular dependency found in these IOLs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of scattering in intraocular lenses by spectrophotometric measurements.

This study presents a method for measuring scattering in explanted intraocular lenses (IOLs). Currently, determining scattering in IOLs is usually performed by Scheimpflug cameras and the results are expressed in the units used by this apparatus. The method we propose uses a spectrophotometer and this makes it possible to measure the total transmission of the IOL by using an integrating sphere;...

متن کامل

Combining in vitro test methods for measuring light scatter in intraocular lenses

Intraocular lenses (IOLs) are designed for implantation for vision correction following cataract removal. The IOL typically replaces a cataractous natural lens that exhibits very high levels of light scattering. The amount of scattering is significantly reduced with an IOL, though it is rarely quantified and both the surface and the bulk of the intraocular lens may contribute to light scatter a...

متن کامل

Determination of the size distribution of monodesperse and bidisperse mixtures of spherical particles in the nanometer and submicron size range by applying cumulant analysis and contin algorithm in dynamic light scattering

Determination of particle size is one of the major needs in the industry and biotechnology. Dynamic light scattering (DLS) is a widely used technique for determining size distribution of spherical particle in nanometer and submicron size range. In this method, there are different algorithms for determining the size and size distribution of particles, which are selected according to the required...

متن کامل

A Computer Modeling of Mie-Scattering by Spherical Droplets Within the Atmosphere

The Earth’s atmosphere is an environment replete with particles of differ-ent sizes with various refractive indices which affect the light radiation traveling through it. The Mie scattering theory is one of the well-known light scattering techniques ap-plicable to modeling of electromagnetic scattering from tiny atmospheric particles or aerosols floating in the air or within the clouds. In this...

متن کامل

Light-scattering characteristics of explanted opacified Aquasense intraocular lenses.

AIM To study forward light-scattering characteristics of calcified explanted intraocular lenses (IOLs) (Aquasense, Ophthalmic Innovation International Ontario). METHODS The amount of light scattered by the opacified IOLs was measured using a validated in vitro set-up for angles from 1.7 degrees to 22 degrees . This set-up gives results directly comparable with straylight values as valid for t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Biomedical optics express

دوره 8 3  شماره 

صفحات  -

تاریخ انتشار 2017