[Optimal setting of focus points for myocardial contrast echocardiography with intravenous Optison (FS-69): an experimental study].
نویسندگان
چکیده
OBJECTIVES Myocardial contrast echocardiography is useful to assess myocardil perfusion, but myocardial opacification is affected by the setup of the ultrasonic equipment. The optimal setting of focus points for adequate opacification of the myocardium was examined in myocardial contrast echocardiography. METHODS Myocardial contrast echocardiography was performed in six dogs using triggered second harmonic technology following intravenous administration of Optison(FS-69). The short-axis view was recorded and baseline subtracted video intensity(peak intensity: PI) was calculated at three regions of the left ventricular wall, the anterior, septum, and posterior walls, to evaluate myocardial opacification. The focus point was set at near(2 cm), middle(4 cm) and far(6 cm)points. The myocardial opacification was evaluated at each focus setting. The effect of the acoustic power was also examined by changing the mechanical index to 1.6, 1.2 or 0.8. RESULTS Myocardial opacification was recognized at all focus points, and segments near the focus points had high PI. However, the PI of the posterior wall was lowest at near focus, whereas the PI of the anterior wall was lowest at far focus. The difference of PI between the anterior and posterior walls was significant (p < 0.05, p < 0.01, respectively) at either focus point. Adequate myocardial opacification of all segments was observed when the focus was set at the middle point. The PI of the whole left ventricle increased relative to mechanical index. CONCLUSIONS Setting up of focus points at the middle of the left ventricle provides more homogeneous myocardial opacification of the whole left ventricle in myocardial contrast echocardiography, and high acoustic power possibly improves myocardial opacification. Inadequate setting of focus points leads to inadequate estimation of myocardial perfusion by myocardial contrast echocardiography.
منابع مشابه
Intravenous myocardial contrast echocardiography predicts recovery of dysynergic myocardium early after acute myocardial infarction.
OBJECTIVES We aimed to ascertain whether triggered intravenous myocardial contrast echocardiography (MCE) can predict functional recovery in patients with acute myocardial infarction (AMI) and to determine the optimal triggering interval in this setting. BACKGROUND Detection of myocardial viability early after AMI has both therapeutic and prognostic implications. Myocardial contrast echocardi...
متن کاملUse of an intravenous contrast agent (Optison) to enhance echocardiography: efficacy and cost implications. Optison Multicenter Study Group.
OBJECTIVE To compare the overall diagnostic costs associated with non-contrast and contrast echocardiography. STUDY DESIGN Phase III clinical trial. PATIENTS AND METHODS In a secondary analysis of data from a phase III clinical trial of the intravenous contrast agent Optison, we compared the costs associated with obtaining a diagnosis in 203 patients who underwent non-contrast and contrast ...
متن کاملSafety of dobutamine stress real-time myocardial contrast echocardiography.
OBJECTIVES The aim of this study was to determine the safety of dobutamine stress myocardial perfusion imaging (MPI) obtained by real-time contrast echocardiography (RTCE) and intravenous ultrasound contrast in a large cohort of patients with suspected coronary artery disease (CAD). BACKGROUND Despite the increasing number of studies showing the potential clinical utility of myocardial contra...
متن کاملWeak concordance between wall motion and microvasculature status after acute myocardial infarction: study with myocardial contrast echocardiography in real time with power modulation.
AIMS The microvasculature damage after myocardial infarction has important implications. The hypothesis of the study was that wall motion abnormalities and microcirculation status do not necessarily match after myocardial infarction, and therefore the study of only myocardial wall motion could offer an incomplete evaluation in these patients. METHODS Wall motion and myocardial perfusion asses...
متن کاملContrast echocardiography: current and future applications.
Recent updates in the field of echocardiography have resulted in improvements in image quality, especially in those patients whose ultrasonographic (ultrasound) evaluation was previously suboptimal. Intravenous contrast agents are now available in the United States and Europe for the indication of left ventricular opacification and enhanced endocardial border delineation. The use of contrast en...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of cardiology
دوره 37 4 شماره
صفحات -
تاریخ انتشار 2001