Metal in Total Hip Arthroplasty: Wear Particles, Biology, and Diagnosis.
نویسندگان
چکیده
Total hip arthroplasty (THA) has been performed for nearly 50 years. Between 2006 and 2012, more than 600,000 metal-on-metal THA procedures were performed in the United States. This article reviews the production of metal wear debris in a metal-on-metal articulation and the interaction of cobalt and chromium ions that ultimately led to a dramatic decline in the use of metal-on-metal THA articulations. Additionally, the article reviews mechanisms of metal wear, the biologic reaction to cobalt and chromium ions, the clinical presentation of failing metal-on-metal articulations, and current diagnostic strategies. Further, the article discusses the use of inflammatory markers, metal ion levels, radiographs, metal artifact reduction sequence magnetic resonance imaging, and ultrasound for failed metal-on-metal THA procedures. When adopting new technologies, orthopedic surgeons must weigh the potential increased benefits against the possibility of new mechanisms of failure. Metal-on-metal bearings are a prime example of the give and take between innovation and clinical results, especially in the setting of an already successful procedure such as THA. [Orthopedics. 2016; 39(6):371-379.].
منابع مشابه
Failure of a metal-on-metal total hip arthroplasty from progressive osteolysis.
Ultra-high-molecular weight polyethylene (UHMWPE) wear, debris-induced osteolysis is a frequent cause of failure of total hip arthroplasty. Metal-on-metal total hip arthroplasty eliminates the generation of UHMWPE particulate debris. Although the volumetric wear of a metal-on-metal articulation may be lower than a metal-UHMWPE articulation, the number of particles may be higher. Osteolysis can ...
متن کاملAccumulation in liver and spleen of metal particles generated at nonbearing surfaces in hip arthroplasty.
Systemic migration of metal particles generated at nonbearing surfaces rather than the intended primary bearing was studied in postmortem specimens from 30 patients with total hip arthroplasty. Using light and electron microscopy with x-ray microanalysis, submicrometer metal particles were identified within macrophages in the liver and/or the spleen in 11 of 15 patients with a revised arthropla...
متن کاملAggressive granulomatosis after cementless total hip arthroplasty as a result of inflammatory reaction to metal debris: case report.
Massive osteolysis and granulomatous pseudotumor tissue reactions are long-term complications of total hip replacement. It is a condition of localized bone resorption in contact with prosthetic material. It is speculated to be a consequence of metal hypersensitivity or inflammatory reaction to excessive wear. Ten years after total cementless hip replacement (metal on polyethylene surface), a 70...
متن کاملFatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature
Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...
متن کاملMetal release and metal allergy after total hip replacement with resurfacing versus conventional hybrid prosthesis
BACKGROUND Metal-on-metal (MOM) total hip arthroplasties were reintroduced because of the problems with osteolysis and aseptic loosening related to polyethylene wear of early metal-on-polyethylene (MOP) arthroplasties. The volumetric wear rate has been greatly reduced with MOM arthroplasties; however, because of nano-size wear particles, the absolute number has been greatly increased. Thus, a s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Orthopedics
دوره 39 6 شماره
صفحات -
تاریخ انتشار 2016