Design, analysis and simulation for development of the first clinical micro-CT scanner.

نویسندگان

  • Ge Wang
  • Shiying Zhao
  • Hengyong Yu
  • Charles A Miller
  • Paul J Abbas
  • Bruce J Gantz
  • Seung Wook Lee
  • Jay T Rubinstein
چکیده

In this article, we propose to develop the first clinical micro-CT (CMCT) system for human temporal bone imaging in vivo. This CMCT system consists of medical CT and micro-CT scanners either as separate components or in a combination, a cross-modality registration mechanism such as a facial surface scanner, and associated software. This system integrates the strengths of state-of-the-art medical CT and micro-CT techniques to achieve a spatial resolution that is much higher than currently available for inner ear imaging at acceptable dose levels. Our design, analysis, and simulation results demonstrate that the CMCT system is feasible for inner ear imaging and other clinical applications. For example, the CMCT system has the potential to improve the safety of guiding cochlear implant electrodes within the inner ear and assist the placement of inner ear microcatheters for delivery of gene modification therapy or administration of neurotrophic factors. Imaging of microarchitectures of the cancellous bone would be also an important application.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of Imaging Parameters in Micro-CT Scanner Based On Signal-To-Noise Ratio for the Analysis of Urinary Stone Composition

Introduction: Micro-CT scanner with a resolution of about 5 micrometers is one of the modalities used to create three-dimensional/two-dimensional images of urinary stones. This study aimed to optimize imaging parameters in micro-computed tomography (CT) scanner based on the signal-to-noise ratio (SNR) of urinary stones for the analysis of stone composition. <stro...

متن کامل

Performance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE

  Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...

متن کامل

Top - Level Design and Preliminary Physical Analysis for the First Electron - Beam Micro - CT Scanner

A state of the art X-ray micro-CT scanner takes about 20 seconds to acquire a full dataset, which is too slow to capture the rapidly beating heart of small animals. We have been working to develop the first electron-beam micro-CT (EBMCT) prototype for cardiac imaging of the mice and rats. In this paper, we describe the background on electron-beam CT (EBCT) and emphasize the needs for EBMCT. The...

متن کامل

Design of Small Animal Computed Tomography Imaging for in vitro and in vivo Studies

Introduction: Mini Computed Tomography (mini-CT) was suggested in biomedical research to investigate tissues and small animals. We present designed and built a mini x-ray computed tomography (mini-CT) for small animals as well as industrial component imaging. Materials and Methods: The system used in this study includes a X-ray tube 20kV to 160kV and a flat pa...

متن کامل

Measurement of organ dose in abdomen-pelvis CT exam as a function of mA, KV and scanner type by Monte Carlo method .

Background: CT is a diagnostic imaging modality giving higher patient dose in comparison with other radiological procedures, so the calculation of organ dose in CT exams is very important. While methods to calculate the effective dose have been established (ICRP 26 and ICRP 60), they depend heavily on the ability to estimate the dose to radiosensitive organs from the CT procedure. However, dete...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Academic radiology

دوره 12 4  شماره 

صفحات  -

تاریخ انتشار 2005