Unrestrained plethysmography is an unreliable measure of airways responsiveness in BALB/c and C57BL6 mice

نویسندگان

  • Andy Adler
  • Greg Cieslewicz
  • Charles G. Irvin
چکیده

There has been significant utilization of the technique described by Hamelmann et al. (1997) in which a parameter, Penh, related to airways responsiveness is non-invasively measured using unrestrained plethysmography (UP). We investigated this technique, seeking to answer these questions: 1) How do changes in Penh compare with changes in traditional plethysmographic and lung mechanical parameters? 2) How do UP parameters perform in two different mouse strains? Awake immunized and control BALB/c (N=16) and C57BL6 (N=14) mice were placed in the UP chamber and exposed to doses of aerosolized methacholine, while the following parameters were measured at each concentration: inspiratory time (TI), expiratory time (TE), total time (TTot), TI/TTot, peak inspiratory pressure (PI), peak expiratory pressure (PE), Pause, Penh, tidal volume (VT), VT/TI, VT/TE, and VT/TTot. The next day, lung resistance and compliance (RL, CL), were invasively measured in the same animals. For the BALB/c, the parameters with the highest magnitude of correlation coefficient vs. RL are (in order): 1) CL, 2) Pause and Penh, 3) parameters of breathing frequency (TE, TTot, TI) and 4) parameters related to tidal volume (PI, PE, VT). Flow parameters (VT/TTot, VT/TE, VT/TI) and duty cycle parameters (TI/TTot) had insignificant correlations. This ordering is significantly different in the C57BL6, where the parameters with the largest correlations are: 1) CL, 2) parameters of breathing frequency, 3) flow parameters. Pause, Penh, tidal volume and duty cycle parameters had insignificant correlations. This data shows that Penh is problematic in the sense that it is strain specific; it behaves very differently in BALB/c and C57BL6 mice. We suggest that UP parameters largely originate as part of reflex control of breathing processes, rather than in the lung mechanics, and conclude that it is inappropriate to use UP parameters in general, and Penh specifically, as substitute variables for invasive mechanical indices such as RL. Adler, Cieslewicz, Irvin Unrestrained plethysmography and airway responsiveness 3/29

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unrestrained plethysmography is an unreliable measure of airway responsiveness in BALB/c and C57BL/6 mice.

There has been significant utilization of the technique described by Hamelmann et al. (Am J Respir Crit Care Med 156: 766-775, 1997) in which a parameter, enhanced pause (Penh), related to airways responsiveness is noninvasively measured by unrestrained plethysmography (UP). Investigating this technique, we sought to answer these questions: 1). How do changes in Penh compare with changes in tra...

متن کامل

Does unrestrained single-chamber plethysmography provide a valid assessment of airway responsiveness in allergic BALB/c mice?

BACKGROUND Unrestrained plethysmography has been used to monitor bronchoconstriction because of its ease of use and ability to measure airway responsiveness in conscious animals. However, its reliability remains controversial. OBJECTIVE To investigate if unrestrained plethysmography could provide a valid interpretation of airway responsiveness in allergic BALB/c mice. METHODS Ovalbumin sens...

متن کامل

Innovative Methodology Restrained whole body plethysmography for measure of strain-specific and allergen-induced airway responsiveness in conscious mice

Lofgren, Jennifer L. S., Melissa R. Mazan, Edward P. Ingenito, Kara Lascola, Molly Seavey, Ashley Walsh, and Andrew M. Hoffman. Restrained whole body plethysmography for measure of strain-specific and allergen-induced airway responsiveness in conscious mice. J Appl Physiol 101: 1495–1505, 2006. First published July 20, 2006; doi:10.1152/japplphysiol.00464.2006.—The mouse is the most extensively...

متن کامل

Innovative Methodology Unrestrained video-assisted plethysmography: a noninvasive method for assessment of lung mechanical function in small animals

Bates JH, Thompson-Figueroa J, Lundblad LK, Irvin CG. Unrestrained video-assisted plethysmography: a noninvasive method for assessment of lung mechanical function in small animals. J Appl Physiol 104: 253–261, 2008. First published October 25, 2007; doi:10.1152/japplphysiol.00737.2007.—The assessment of lung mechanical function in small animals, particularly mice, is essential for investigation...

متن کامل

Noninvasive measurement of airway responsiveness in allergic mice using barometric plethysmography.

To study the mechanisms and kinetics underlying the development of increased airway responsiveness (AR) after allergic sensitization, animal models have been invaluable. Using barometric whole-body plethysmography and increases in enhanced pause (Penh) as an index of airway obstruction, we measured responses to inhaled methacholine in conscious, unrestrained mice after sensitization and airway ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004