Cortical hypertrophy with a short, curved uncemented hip stem does not have any clinical impact during early follow-up
نویسندگان
چکیده
BACKGROUND Short stems have become more and more popular for cementless total hip arthroplasty in the past few years. While conventional, uncemented straight stems for primary total hip arthroplasty (THA) have shown high survival rates in the long term, it is not known whether uncemented short stems represent a reasonable alternative. As cortical hypertrophy has been reported for short stems, the aim of this study was to determine the radiographic prevalence of cortical hypertrophy and to assess the clinical outcome of a frequently used short, curved hip stem. METHODS We retrospectively studied the clinical and radiographic results of our first 100 consecutive THAs (97 patients) using the Fitmore® hip stem. Mean age at the time of index arthroplasty was 59 years (range, 19 - 79 years). Clinical outcome and radiographic results were assessed with a minimum follow-up of 2 years, and Kaplan-Meier survivorship analysis was used to estimate survival for different endpoints. RESULTS After a mean follow-up of 3.3 years (range, 2.0 - 4.4 years), two patients (two hips) had died, and three patients (four hips) were lost to follow-up. Kaplan-Meier analysis estimated a survival rate of 100 % at 3.8 years, with revision for any reason as the endpoint. No femoral component showed radiographic signs of loosening. No osteolysis was detected. Cortical hypertrophy was found in 50 hips (63 %), predominantly in Gruen zone 3 and 5. In the cortical hypertrophy group, two patients (two hips; 4 %) reported some thigh pain in combination with pain over the greater trochanter region during physical exercise (UCLA Score 6 and 7). There was no significant difference concerning the clinical outcome between the cortical hypertrophy and no cortical hypertrophy group. CONCLUSIONS The survival rate and both clinical and the radiographic outcome confirm the encouraging results for short, curved uncemented stems. Postoperative radiographs frequently displayed cortical hypertrophy but it had no significant effect on the clinical outcome in the early follow-up. Further clinical and radiographic follow-up is necessary to detect possible adverse, long-term, clinical effects of cortical hypertrophy.
منابع مشابه
A Single Femoral Component for All Total Hip Replacements Performed by a Trust? Does This Affect Early Clinical and Radiological Outcomes?
Background: Hospitals may be under pressure to implement cost saving strategies regarding prosthesis choice. Thismay involve the use of components which are not the first preference of individual surgeons, or those they have littleexperience with. We aim to examine the effect of standardizing the type of femoral stem used in a single trust, anddetermine whether this is safe practice, particular...
متن کاملPoor intermediate-term survival of the uncemented Optan anatomically adapted femoral component
PURPOSE We evaluated the 5-year survival of the uncemented Optan anatomically adapted femoral stem, with revision for aseptic loosening as the endpoint. METHODS Between January 2004 and March 2007, 432 total hip arthroplasties (THAs) were performed in 432 patients. After follow-up for a mean time of 5 years, the patients were evaluated using the WOMAC questionnaire and plain radiography. Pati...
متن کاملStable, dependable fixation of short-stem femoral implants at 5 years.
Conventional uncemented femoral implants provide dependable long-term fixation in patients with a wide range of clinical function. However, challenges with proximal-distal femoral mismatch, preservation of bone stock, and minimally invasive approaches have led to exploration into various other implant designs. Short-stem designs focusing on a stable metaphyseal fit have emerged to address these...
متن کاملShort-term Outcomes With a Second-Generation Uncemented Stem in Total Hip Arthroplasty.
An uncemented stem has been used successfully in total hip arthroplasty for 2 decades, and some implants have been updated. The authors have used second-generation uncemented proximal porous coating stems, the Echo Bi-Metric Full Proximal Profile stem (Echo FPP; Biomet, Warsaw, Indiana) and the Echo Reduced Proximal Profile stem (Echo RPP; Biomet). This article reports short-term outcomes with ...
متن کاملMid-term results of previously cemented hip arthroplasties revised with uncemented modular femoral components: a retrospective study
BACKGROUND We evaluated the mid-term results of previously cemented hip arthroplasties revised with uncemented modular femoral components. METHODS The study included 40 patients (36 females (90 %) and 4 males (10 %), mean age 67.6 years, range 39-87 years) who underwent revision of a previously cemented hip prosthesis with an uncemented modular femoral stem between 2005 and 2009. The indicati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -
تاریخ انتشار 2015