Ventricular pacemaker upgrade: experience, complications, and recommendations.
نویسندگان
چکیده
OBJECTIVE To assess outcomes of pacemaker upgrade from single chamber ventricular to dual chamber. DESIGN Retrospective analysis of patients undergoing the procedure. SETTING Specialist cardiothoracic unit. PATIENTS 44 patients (15 female, 29 male), mean (SD) age at upgrade 68.2 (12.9) years. INTERVENTIONS Upgrade of single chamber ventricular to dual chamber pacemaker. MAIN OUTCOME MEASURES Procedure duration and complications. RESULTS Principal indications for upgrade were pacemaker syndrome (17), "opportunistic"--that is, at elective generator replacement (8), heart failure (7), non-specific breathlessness/fatigue (7), and neurally mediated syncope (3). Mean (SD) upgrade procedure duration (82.9 (32.6) minutes) significantly exceeded mean VVI implantation duration (42.9 (13.3) minutes) and mean DDD implantation duration (56.6 (22.7) minutes) (both p < 0.01). Complications included pneumothorax (1), ventricular arrhythmia requiring cardioversion (2), protracted procedure (10), atrial lead repositioning within six weeks (8), haematoma evacuation (1), superficial infection (1), and admission to hospital with chest pain (1); 20 patients (45%) suffered one or more complications including four of the eight who underwent opportunistic upgrade. CONCLUSIONS Pacemaker upgrade takes longer and has a higher complication rate than either single or dual chamber pacemaker implantation. This suggests that the procedure should be performed by an experienced operator, and should be undertaken only if a firm indication exists. Patients with atrial activity should not be offered single chamber ventricular systems in the belief that the unit can be upgraded later if necessary at minimal risk.
منابع مشابه
Pacemaker Twiddler's Syndrome
A 76-yr-old man with unipolar ventricular pacemaker, previously implanted in the right ventricular apex, presented with syncopal attack and twitching of the right pectoralis muscle. He finally was diagnosed as having Twiddler's syndrome. The patient had a pulse rate of 36/min and cannon waves in the neck veins. Chest radiography showed a dislodged pacing lead completely wrapped around the pulse...
متن کاملEffects of Upgrade Versus De Novo Cardiac Resynchronization Therapy on Clinical Response and Long-Term Survival
The beneficial impact of newly implanted cardiac resynchronization therapy (CRT) on morbidity and mortality are well described in selected patients with heart failure. Patients with heart failure already fitted with a conventional pacemaker or implantable cardioverter defibrillator (ICD) system are often considered for a CRT upgrade after the new development of CRT criteria (ie, new left bundle...
متن کاملCARDIOVASCULAR MEDICINE Long term complications in single and dual chamber pacing are influenced by surgical experience and patient morbidity
Objective: To determine how short and long term complication rates after pacemaker implantation are influenced by patient morbidity, operator experience, and choice of pacing system. Design: Retrospective analysis of 1884 patients who received VVI (n = 610), VDD (n = 371), or DDD devices (n = 903) between 1990 and 2001. Follow up period was 64 (34) months. The influence of age, sex, coronary ar...
متن کاملInfluence of heart failure etiology on the effect of upgrading from right ventricular apical to biventricular or bifocal pacing in patients with permanent atrial fibrillation and advanced heart failure.
INTRODUCTION Chronic heart failure (HF) results from various disease processes. There are no data on the effect of the etiology of HF on the improvement after pacemaker upgrade. OBJECTIVES The aim of the study was to assess changes in various parameters in patients with ischemic (IC) and nonischemic (NIC) cardiomyopathy after pacemaker upgrade in pacemaker-dependent patients with permanent atri...
متن کاملCardiac arrest caused by a pacemaker check.
To cite: Orsborne C, Morris GM, Brown BD. BMJ Case Rep Published online: [please include Day Month Year] doi:10.1136/bcr-2014206621 DESCRIPTION A 75-year-old man attended a yearly pacemaker check. His VVIR device was inserted in 2008 for atrial fibrillation with a slow ventricular rate. He subsequently developed ischaemic cardiomyopathy, severely impaired left ventricular (LV) function and unde...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Heart
دوره 79 4 شماره
صفحات -
تاریخ انتشار 1998