Interferometric Bloch-Siegert B1+ mapping at 7T

نویسندگان

  • Patrik Wyss
  • Shaihan J Malik
  • Vincent O Boer
  • Johanna J Bluemink
  • Alexander Raaijmakers
  • Mustafa Cavusoglu
  • Peter Luijten
  • Johannes J Hoogduin
  • Giel Mens
  • Anke Henning
چکیده

Patrik Wyss, Shaihan J Malik, Vincent O Boer, Johanna J Bluemink, Alexander Raaijmakers, Mustafa Cavusoglu, Peter Luijten, Johannes J Hoogduin, Giel Mens, and Anke Henning Institute for Biomedical Engineering, UZH and ETH Zurich, Zurich, Switzerland, Imaging Sciences and Biomedical Engineering, Kings College London, London, United Kingdom, University Medical Center Utrecht, Utrecht, Netherlands, Philips Healthcare, Best, Netherlands, Max Planck Institute for Biological Cybernetics, Tübingen, Germany

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast and Robust B1 Mapping at 7T by the Bloch-Siegert Method

Introduction: B1 mapping has a variety of applications including the design of RF pulses in parallel transmit systems, and flip angle calibration for T1 mapping. Many existing B1 mapping methods suffer from T1 dependence, long scan time or inability to handle the large B1 inhomogeneity that occurs even across the human brain at 7T. The Bloch-Siegert B1 mapping method has been recently introduce...

متن کامل

Bloch‐Siegert B1+‐mapping for human cardiac 31P‐MRS at 7 Tesla

PURPOSE Phosphorus MR spectroscopy ((31) P-MRS) is a powerful tool for investigating tissue energetics in vivo. Cardiac (31) P-MRS is typically performed using surface coils that create an inhomogeneous excitation field across the myocardium. Accurate measurements of B1+ (and hence flip angle) are necessary for quantitative analysis of (31) P-MR spectra. We demonstrate a Bloch-Siegert B1+-mappi...

متن کامل

Motion-robust cardiac B1+ mapping at 3T using interleaved bloch-siegert shifts.

PURPOSE To develop and evaluate a robust motion-insensitive Bloch-Siegert shift based B1+ mapping method in the heart. METHODS Cardiac Bloch-Siegert B1+ mapping was performed with interleaved positive and negative off-resonance shifts and diastolic spoiled gradient echo imaging in 12 heartbeats. Numerical simulations were performed to study the impact of respiratory motion. The method was com...

متن کامل

Turbo Spin Echo Bloch Siegert Shift B1 Mapping

An interesting method for B1 mapping based on the Bloch-Siegert (BLS) shift was recently presented (1,2) for gradient echo (FLASH) and Spin Echo (SE) sequences. This method uses off-resonant pulses before signal acquisition to encode the B1 information into the signal phase. Fast B1 mapping is possible since the repetition time has only minor influence on the quality of the phase information. I...

متن کامل

Signal to Noise Ratio Analysis of Bloch-Siegert B1 Mapping

Introduction: B1 mapping is important in a variety of new MR applications, including the design of RF pulses in parallel transmit systems and flip angle calibration for T1 mapping. The Bloch-Siegert (BS) B1 mapping method has been recently introduced as a fast, accurate and robust technique for B1 mapping [1]. In order to compare the quality of B1 maps acquired with the BS method to other metho...

متن کامل