Nonlinearity Measurements of High-Power Laser Detectors at NIST

نویسندگان

  • Xiaoyu Li
  • Thomas Scott
  • Shao Yang
  • Chris Cromer
  • Marla Dowell
چکیده

We briefly explain the fundamentals of detector nonlinearity applicable to both electrical and optical nonlinearity measurements. We specifically discuss the attenuation method for optical nonlinearity measurement that the NIST system is based upon, and we review the possible sources of nonlinearity inherent to thermal detectors used with high-power lasers. We also describe, in detail, the NIST nonlinearity measurement system, in which detector responsivity can be measured at wavelengths of 1.06 µm and 10.6 µm, over a power range from 1 W to 1000 W. We present the data processing method used and show measurement results depicting both positive and negative nonlinear behavior. The expanded uncertainty of a typical NIST high-power laser detector calibration including nonlinearity characterization is about 1.3 %.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Steady-State Brillouin Nonlinearity in High-Power Fiber Lasers

In the present work, a theoretical analysis of the first-order of stimulatedBrillouin scattering (SBS) in a double-clad (DC) ytterbium (Yb)-doped silica fiber laserin unidirectional pumping mode is presented.An accurate simulation for calculating SBS nonlinearity is performed by considering thecoupled differential rate equations for pump, signal and Stokes powers, as wel...

متن کامل

Reflective Optical Chopper Used in NIST High-Power Laser Measurements

For the past ten years, NIST has used high-reflectivity, optical choppers as beamsplitters and attenuators when calibrating the absolute responsivity and response linearity of detectors used with high-power CW lasers. The chopper-based technique has several advantages over the use of wedge-shaped transparent materials (usually crystals) often used as beam splitters in this type of measurement s...

متن کامل

Intramural Comparison of NIST Laser and Optical Fiber Power Calibrations

The responsivity of two optical detectors was determined by the method of direct substitution in four different NIST measurement facilities. The measurements were intended to demonstrate the determination of absolute responsivity as provided by NIST calibration services at laser and optical-communication wavelengths; nominally 633 nm, 850 nm, 1060 nm, 1310 nm, and 1550 nm. The optical detectors...

متن کامل

The NIST High Accuracy Scale for Absolute Spectral Response from 406 nm to 920 nm

We describe how the National Institute of Standards and Technology obtains a scale of absolute spectral response from 406 nm to 920 nm. This scale of absolute spectral response is based solely on detector measurements traceable to the NIST High Accuracy Cryogenic Radiometer (HACR). Silicon photodiode light-trapping detectors are used to transfer optical power measurements from the HACR to a mon...

متن کامل

Optical Fiber Power Meter Calibrations at NIST

The optical fiber power meter (OFPM) is perhaps the most common type of test equipment used to support the development and implementation of optical fiber systems. To address the inherent metrology requirements, NIST has developed and implemented measurement services to help characterize these instruments [1]. These measurement services consist primarily of absolute laser power calibrations usi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 109  شماره 

صفحات  -

تاریخ انتشار 2004