By the Measurements of Helium and Watek V .
نویسنده
چکیده
Information is now available regarding the vertical distribution of water vapour and helium in the lower stratosphere over southern England. The helium content of the air is found to be remarkably constant up to 2 0 km but the water content is found to fall very rapidly just above the tropopause, and in the lowest I km of the stratosphere the humidity mixing ratio falls through a ratio of 10-1. The helium distribution is not compatible with the view of a quiescent stratosphere free from turbulence or vertical motions. The water-vapour distribution is incompatible with a turbulent stratosphere unless some dynamic process maintains the dryness of the stratosphere. In view of the large wind shear which is normally found just above the tropopause it is unlikely that this region is free from turbulence. The observed distributions can be explained by the existence of a circulation in which air enters the stratosphere a t the equator, where it is dried by condensation, travels in the stratosphere to temperate and polar regions, and sinks into the troposphere. The sinking, however, will warm the air unless it is being cooled by radiation and the idea of a stratosphere in radiative equilibrium must be abandoned. The cooling rate must lie between about 0 . 1 and I . I " C per day but a value near o.g°C per day seems most probablc. At the equator the ascending air must be subject to heating by radiation. The circulation is quite reasonable on energy considerations. I t is consistent with the existence of lower temperatures in the equatorial stratosphere than in polar and temperate regions, and if the flow can carry ozone from the equator to the poles then it gives a reasonable explanation of the high ozone values observed a t high latitudes. The dynamic consequences of the circulation are not considered. I t should however be noted that there is considerable difficulty to account for the smallness of the westerly winds in the stratosphere, as the rotation of the earth should convert the slow poleward movement into strong westerly winds.
منابع مشابه
Design and construction of a helium purification system using cryogenic adsorption process
One of the most appropriate methods for elimination of trace impurities in helium is cryogenic adsorption process. So, in this study design and construction of cryogenic adsorption helium purification system (3 Nm3.hr-1, 80 bar) carried out using activated carbon as adsorbent at 77K. To evaluation of adsorption dynamics and effect of pressure on elimination of trace impurities, helium purificat...
متن کاملEEDF MEASUREMENTS AND EXCITATION PROCESSES IN THE VICINITY OF A HELIUM DISCHARGE CONSTRICTION
Axial distributions of plasma and floating potentials, electron number density and the electron energy distribution function (EEDF) have been measured in the double layer (DL) region of an He discharge constriction. Excitation processes in the constriction region are studied. Using a linearization method for the nonstationary balance equations and choosing appropriate discharge conditions, ...
متن کاملEvaluation of the Effects of Different Filters and Helium Bag on the Reduction of Electron Contamination in Photon Beam of Neptun Linac
Introduction: Skin sparing is one of the most desirable characteristics of high energy photon beams. However, the photons emerging from the target of linacs are contaminated by secondary electrons as a result of their interactions with air, collimators, flattening filter and any other objects in their path. This phenomenon tends to increase the skin dose received b...
متن کاملAccurate characteristics of Helium in nano-channels
This article describes an accurate subPico flowmeter bifurcatedin to liquid and gas flowrates less than 1mol/s for both MEMS/NEMS and cryogenic technology applications. The MEMS/NEMS are described as either two Gauges (instrument), or quartz fluctuating forks, even if the liquid or gas flows through an element, as well as cryogenic technology consisting of arrays of e...
متن کاملAccurate characteristics of Helium in nano-channels
This article describes an accurate subPico flowmeter bifurcatedin to liquid and gas flowrates less than 1mol/s for both MEMS/NEMS and cryogenic technology applications. The MEMS/NEMS are described as either two Gauges (instrument), or quartz fluctuating forks, even if the liquid or gas flows through an element, as well as cryogenic technology consisting of arrays of e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1949