Concordance of Macular Pigment Measurement Using Customized Heterochromatic Flicker Photometry and Fundus Autofluorescence in Age-Related Macular Degeneration.

نویسندگان

  • Kwadwo Owusu Akuffo
  • Stephen Beatty
  • Jim Stack
  • Tunde Peto
  • Irene Leung
  • Laura Corcoran
  • Rebecca Power
  • John M Nolan
چکیده

PURPOSE We compared macular pigment (MP) measurements using customized heterochromatic flicker photometry (Macular Metrics Densitometer) and dual-wavelength fundus autofluorescence (Heidelberg Spectralis HRA + OCT MultiColor) in subjects with early age-related macular degeneration (AMD). METHODS Macular pigment was measured in 117 subjects with early AMD (age, 44-88 years) using the Densitometer and Spectralis, as part of the Central Retinal Enrichment Supplementation Trial (CREST; ISRCTN13894787). Baseline and 6-month study visits data were used for the analyses. Agreement was investigated at four different retinal eccentricities, graphically and using indices of agreement, including Pearson correlation coefficient (precision), accuracy coefficient, and concordance correlation coefficient (ccc). RESULTS Agreement was poor between the Densitometer and Spectralis at all eccentricities, at baseline (e.g., at 0.25° eccentricity, accuracy = 0.63, precision = 0.35, ccc = 0.22) and at 6 months (e.g., at 0.25° eccentricity, accuracy = 0.52, precision = 0.43, ccc = 0.22). Agreement between the two devices was significantly greater for males at 0.5° and 1.0° of eccentricity. At all eccentricities, agreement was unaffected by cataract grade. CONCLUSIONS In subjects with early AMD, MP measurements obtained using the Densitometer and Spectralis are not statistically comparable and should not be used interchangeably in either the clinical or research setting. Despite this lack of agreement, statistically significant increases in MP, following 6 months of supplementation with macular carotenoids, were detected with each device, confirming that these devices are capable of measuring change in MP within subjects over time. (http://www.controlled-trials.com number, ISRCTN13894787.).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Concordance of macular pigment measurements obtained using customized heterochromatic flicker photometry, dual-wavelength autofluorescence, and single-wavelength reflectance.

This study compares in vivo measurements of macular pigment (MP) obtained using customized heterochromatic flicker photometry (cHFP; Macular Metrics Densitometer(™)), dual-wavelength fundus autofluorescence (Heidelberg Spectralis(®) HRA + OCT MultiColor) and single-wavelength fundus reflectance (Zeiss Visucam(®) 200). MP was measured in one eye of 62 subjects on each device. Data from 49 subjec...

متن کامل

Clinical and Epidemiologic Research The Heritability of Macular Response to Supplemental Lutein and Zeaxanthin: A Classic Twin Study

METHODS. A total of 322 healthy female twin volunteers, aged 16–50 years (mean 40 6 8.7) was enrolled in a prospective, nonrandomized supplement study. Macular pigment optical density (MPOD) measurements using two techniques (2wavelength fundus autofluorescence [AF] and heterochromatic flicker photometry [HFP]), and serum concentrations of L and Z, were recorded at baseline, and at 3 and 6 mont...

متن کامل

The utility of using customized heterochromatic flicker photometry (cHFP) to measure macular pigment in patients with age-related macular degeneration.

The purpose of this study was to assess the utility and validity of using customized heterochromatic flicker photometry (cHFP) to measure macular pigment optical density (MPOD) in patients with intermediate stages of age-related macular degeneration (AMD). The measurement procedure was optimized to accommodate individual differences in temporal vision related to age, disease, or other factors. ...

متن کامل

Comparison between macular pigment optical density measurements using two-wavelength autofluorescence and heterochromatic flicker photometry techniques.

PURPOSE The association of macular pigment (MP) with age-related macular degeneration has been extensively studied in recent years, and interest in a rapid, objective, and accurate technique to measure MP optical density (MPOD) has increased. The purpose of this study was to compare the MPOD values at specific loci around the fovea using the heterochromatic flicker photometry (HFP) and the two-...

متن کامل

Macular pigment optical density spatial distribution measured in a subject with oculocutaneous albinism.

PURPOSE Previous studies of macular pigment optical density (MPOD) distribution in individuals with oculocutaneous albinism (OCA) have primarily used objective measurement techniques including fundus reflectometry and autofluorescence. We report here on a subject with OCA and their corresponding MPOD distribution assessed through heterochromatic flicker photometry (HFP). METHODS A subject wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 56 13  شماره 

صفحات  -

تاریخ انتشار 2015