Safety Profile of a Miniaturized Insertable Cardiac Monitor: Results from Two Prospective Trials.

نویسندگان

  • Suneet Mittal
  • Prashanthan Sanders
  • Evgeny Pokushalov
  • Lukas Dekker
  • Dean Kereiakes
  • Edward J Schloss
  • Erika Pouliot
  • Noreli Franco
  • Yan Zhong
  • Marco DI Bacco
  • Helmut Pürerfellner
چکیده

BACKGROUND Insertable cardiac monitors (ICMs) are used to continuously monitor the patient's electrocardiogram. In response to patient activation or based on automated device algorithms, arrhythmia episodes are stored and automatically transmitted daily to the clinician. Thus, ICMs can be used to diagnose arrhythmias in at-risk patients and in those with symptoms potentially attributable to arrhythmias. The ICM described in this report has undergone a dramatic change in size and method of insertion. METHODS To evaluate the safety profile of the ICM procedure, we analyzed procedure-related adverse events (AEs) from two separate trials: A controlled, nonrandomized multicenter study (Reveal LINQ(TM) Usability study) and a multicenter registry (Reveal LINQ(TM) Registry) evaluating real-world experience. For the Registry we reported all procedure-related AEs upon occurrence, whereas for the Usability study, we reported events occurring during the first month of follow-up. RESULTS The Usability study enrolled 151 patients (age 56.6 ± 12.1 years; male 67%) at 16 centers; during follow-up, an infection was observed in 1.3% patients and a procedure-related serious AE (SAE) in 0.7% patients. The Registry enrolled 122 patients (age 61.0 ± 17.8 years; male 47%) at seven centers; during follow-up, an infection was observed in 1.6% patients and a procedure-related SAE in 1.6% patients. CONCLUSIONS The cumulative experience from a controlled clinical trial and a "real-world" registry demonstrate that the new ICM can be inserted with very low incidence of AEs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implant Evaluation of an Insertable Cardiac Monitor Outside the Electrophysiology Lab Setting

BACKGROUND To date, insertable cardiac monitors (ICM) have been implanted in the hospital without critical evaluation of other potential settings. Providing alternatives to in-hospital insertion may increase access to ICM, decrease waiting times for patients awaiting diagnosis, and reduce hospital resources. METHODS This was a prospective, non-randomized, clinical trial involving nine clinica...

متن کامل

Frequency of Cardiac Arrhythmias in Patients with Aluminum Phosphide Poisoning

Background: Cardiac failure is the major lethal consequence of aluminum phosphide (AlP) poisoning. This study was designed to determine the frequency of cardiac arrhythmias in patients with AlP poisoning. Methods: In this prospective cross-sectional study, patients with definitive history of AlP poisoning treated at emergency department of Allied Hospital Faisalabad, Faisalabad, Pakistan, from ...

متن کامل

A Systematic Review and Meta-Analysis of Randomized Controlled Trials Comparing the Safety of Dapagliflozin in Type 1 Diabetes Patients

Background and Purpose: The dapagliflozin’s safety profile in insulin-treated adult type-1 diabetes mellites (T1DM) patients remains poorly explored. Therefore, this systematic review and meta-analysis compared the risk of all-cause side effects, study discontinuation of participants due to side effects, urinary tract infection (UTI), diabetic ketoacidosis, and hypoglycemia between dapagliflozi...

متن کامل

Accurate diagnosis of convulsive syncope: role of an implantable subcutaneous ECG monitor

Convulsive syncope due to transient bradycardia is recognized as a cause of treatment-resistant seizures. However, the diagnosis may be difficult to make with conventional electrocardiographic devices if attacks are infrequent. We present a case of apparent epilepsy in which a new implantable electrocardiographic event recorder (the 'Reveal' insertable loop recorder) was used to show that attac...

متن کامل

An Investigation of Safety and Efficacy of Intravenous Paracetamol in Pain Management Following Cardiac Surgery

Introduction: Optimum pain management immediately after surgeries can lower the possibility of pain syndrome and its following consequences. Opioids are amongst the analgesics used for postoperative pain control; however, their application can bring about several adverse effects. In this study, all the published articles regarding efficacy of Paracetamol   in post-cardiac surgery pain managemen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 38 12  شماره 

صفحات  -

تاریخ انتشار 2015