Chemiluminescence determination of surfactant Triton X-100 in environmental water with luminol-hydrogen peroxide system

نویسندگان

  • Xiaoyu Liu
  • Aifang Li
  • Baohui Zhou
  • Chaokun Qiu
  • Hongmin Ren
چکیده

BACKGROUND The rapid, simple determination of surfactants in environmental samples is essential because of the extensive use and its potential as contaminants. We describe a simple, rapid chemiluminescence method for the direct determination of the non-ionic surfactant Triton X-100 (polyethylene glycol tert-octylphenyl ether) in environmental water samples. The optimized experimental conditions were selected, and the mechanism of the Luminol-H2O2-Triton X-100 chemiluminesence system was also studied. RESULTS The novel chemiluminescence method for the determination of non-ionic surfactant Triton X-100 was based on the phenomenon that Triton X-100 greatly enhanced the CL signal of the luminol-H2O2 system. The alkaline medium of luminol and the pH value obviously affected the results. Luminol concentration and hydrogen peroxide concentration also affected the results. The optimal conditions were: Na2CO3 being the medium, pH value 12.5, luminol concentration 1.0 x 10(-4) mol L(-1), H2O2 concentration 0.4 mol L(-1). The possible mechanism was studied and proposed. CONCLUSION Under the optimal conditions, the standard curve was drawn up and quotas were evaluated. The linear range was 2 x 10(-4) g mL(-1)-4 x 10(-2) g mL(-1) (w/v), and the detection limit was 3.97 x 10-5 g mL(-1) Triton X-100 (w/v). The relative standard deviation was less than 4.73% for 2 x 10(-2) g mL(-1) (w/v) Triton X-100 (n = 7). This method has been applied to the determination of Triton X-100 in environmental water samples. The desirable recovery ratio was between 96%-102% and the relative standard deviation was 2.5%-3.3%. The luminescence mechanism was also discussed in detail based on the fluorescence spectrum and the kinetic curve, and demonstrated that Triton X-100-luminol-H2O2 was a rapid reaction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectrophotometric Determination of Acidity Constants of Thiamine in Water, Water-Triton X-100 Micellar Media Solutions

In this work the acidity constants of Thiamine in water and water-Triton X-100 micelle media solutions, at 25 °C, have been determined spectrophotometrically. To evaluate the pH- absorbance data, a resolution based on the combination of soft-and hard-modeling is applied. The acidity constants of all related equilibria are estimated using the whole spectral fitting of the collected data to a...

متن کامل

Chemiluminescence Determination of Atropine using Luminol-Hemin-H2O2 System

A sensitive and fast chemiluminescence (CL) method has been described for the direct determination of atropine. The method is based on the quenching effect of atropine on the CL signals of the luminol– H2O2 reaction catalyzed by hemin in an alkaline medium. Hemin could strongly enhance the chemiluminescence of the luminol–H2O2 system. The luminophor of the luminol–H2O2–hemin CL system was ident...

متن کامل

Ultrasensitive assay of azithromycin in medicine and bio-fluids based on its enhanced luminol-H(2)O(2) chemiluminescence reaction using flow injection technique.

A simple flow injection chemiluminescence method with synergistic enhancement has been investigated for the rapid and sensitive determination of azithromycin. The synergistic action was significant in the chemiluminescence system of luminol-hydrogen peroxide with azithromycin as an enhancer. The enhanced chemiluminescence intensity was linear with the concentration of azithromycin over the rang...

متن کامل

Studies on PVP hydrogel-supported luminol chemiluminescence: 2. Luminometer calibration and potential analytical applications.

The use of poly(N-vinyl-2-pyrrolidone) (PVP) hydrogel-supported luminol chemiluminescence (CL) for the automatic determination of hydrogen peroxide and the quantification of the antiradical capacity of Trolox is described. The hydrogel containing luminol and hemin is prepared directly on a 96-well microplate and can be stored for up to 3 months without significant decrease in CL quantum yields....

متن کامل

Passive micromixer for luminol-peroxide chemiluminescence detection.

This paper reports a microchip with an integrated passive micromixer based on chaotic advection. The micromixer with staggered herringbone structures was used for luminol-peroxide chemiluminescence detection. The micromixer was examined to assess its suitability for chemiluminescence reaction. The relationship between the flow rate and the location of maximum chemiluminescence intensity was inv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chemistry Central Journal

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2009