Midterm survival of a contemporary modular total knee replacement: a multicentre study of 1970 knees.

نویسندگان

  • D F Dalury
  • W P Barrett
  • J B Mason
  • W M Goldstein
  • J A Murphy
  • M W Roche
چکیده

This retrospective study evaluated the midterm clinical and radiographic outcomes of a second-generation total knee replacement system. In a multicentre consecutive series of 1512 patients, 1970 knees were treated with the PFC Sigma knee system (Depuy, Warsaw, Indiana). The patients were reviewed for functional outcome, and underwent independent radiographic evaluation at a mean follow-up of 7.3 years (5 to 10). A total of 40 knees (2%) required revision, 17 (0.9%) for infection. The incidence of osteolysis was 2.2%. The ten-year survival with revision for any cause other than infection as the endpoint was 97.2% (95% CI 95.4 to 99.1). The PFC Sigma knee system appears to provide excellent results in the medium term.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Midterm results of cemented Press Fit Condylar Sigma total knee arthroplasty system.

PURPOSE To evaluate the midterm results of 50 patients who underwent total knee replacement using Press Fit Condylar (PFC) Sigma system. METHODS We retrospectively reviewed 87 consecutive cases (50 patients with 37 bilateral cases) of PFC Sigma total knee replacement performed between January 1998 and December 1999. Patients were evaluated clinically and radiographically by an independent obs...

متن کامل

Better Survival of Total Knee Replacement in Patients Older Than 70 Years: A Prospective Study with 8 To 12 Years Follow-Up

 Background: Modern knee designs have popularized its use in younger patients due to its better performance. There remains uncertainty whether higher demands of these patients can affect implant survivorship.    Purpose: To assess whether modern knee designs have provided similar results in patients younger than 70 years versus older patients. Methods: We included 203 consecutive patients (236 ...

متن کامل

Osteolysis in a surface-cemented, primary, modular Freeman-Samuelson total knee replacement.

We analysed at a mean follow-up of 7.25 years the clinical and radiological outcome of 117 patients (125 knees) who had undergone a primary, cemented, modular Freeman-Samuelson total knee replacement. While the tibial and femoral components were cemented, the patellar component was uncemented. A surface-cementing technique was used to secure the tibial components. A total of 82 knees was availa...

متن کامل

Modular, mobile-bearing hinge total knee arthroplasty.

Early reports of hinge total knee arthroplasty showed high rates of complications and implant failure. Third-generation modular, mobile-bearing, hinge knee arthroplasty systems have evolved to decrease the deleterious stresses that contributed to the failures of earlier designs. The combined series of Barrack et al and Jones et al documents midterm results using the S-ROM Hinge Knee System for ...

متن کامل

Midterm outcomes of electromagnetic computer-assisted navigation in minimally invasive total knee arthroplasty

BACKGROUND A combination of two emerging technologies, computer-assisted navigation and minimally invasive surgery, in total knee arthroplasty has gained increasing interests from orthopedic surgeons around the world. To date, there has never been any midterm study for clinical and radiographic outcomes from using an electromagnetic computer-assisted navigation system. In this study, we aimed t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 90 12  شماره 

صفحات  -

تاریخ انتشار 2008