Blood velocities estimation using ultrasound
نویسندگان
چکیده
This thesis consists of two parts. In the first part, the iterative data-adaptive BIAA spectral estimation technique was extended to estimate lateral blood velocities using ultrasound scanners. The BIAA method makes no assumption on samples depth or sampling pattern, and therefore allows for transmission in duplex mode imaging. The technique was examined on a realistic Field II simulation data set, and showed fewer spectral artifacts in comparison with other techniques. In the second part of the thesis, another common problem in blood velocity estimation has been investigated, namely strong backscattered signals from stationary echoes. Two methods have been tested to examine the possibility of overcoming this problem. However, neither of these methods resulted in a better estimation of the blood velocities, most likely as the clutter characteristics in color flow images vary too rapidly to allow for this form of models. This might be a result of the non-stationary tissue motions which could be caused by a variety of factors, such as cardiac activities, respiration, transducer/patient movement, or a combination of them.
منابع مشابه
Range/velocity limitations for time-domain blood velocity estimation.
The traditional range/velocity limitation for blood velocity estimation systems using ultrasound is elucidated. It is stated that the equation is a property of the estimator used, not the actual physical measurement situation, as higher velocities can be estimated by the time domain cross-correlation approach. It is demonstrated that the time domain technique under certain measurement condition...
متن کاملArtifacts in Blood Velocity Estimation Using Ultrasound and Cross-correlation Artifacts in Blood Velocity Estimation Using Ultrasound and Cross-correlation
Estimation of blood velocities using ultrasound and time-domain cross-correlation is investigated. The measurement principle is introduced and the basic properties of the cross-correlation function is discussed. Expressions for the variance of the estimates of the peak location are given showing the innuence of integration time, transducer bandwidth and signal-to-noise ratio. It is also shown t...
متن کاملSimultaneous quantification of myocardial and blood flow velocities based on duplex mode ultrasound imaging
BACKGROUND Ultrasound imaging of the heart is a commonly used clinical tool to assess cardiac function. The basis for this analysis is the quantification of cardiac blood flow and myocardial velocities. These are typically measured using different imaging modes and on different cardiac cycles. However, due to beat-to-beat variations such as irregular heart rhythm and transient events, simultane...
متن کاملCan echocardiographic particle image velocimetry correctly detect motion patterns as they occur in blood inside heart chambers? A validation study using moving phantoms
AIMS To validate Echo Particle Image Velocimetry (PIV) METHODS: High fidelity string and rotating phantoms moving with different speed patterns were imaged with different high-end ultrasound systems at varying insonation angles and frame rates. Images were analyzed for velocity and direction and for complex motion patterns of blood flow with dedicated software. Post-processing was done with MAT...