INTRODUCTION AND OBJECTIVES Initial preclinical studies are required during the process of improving polymers, platforms, and drug-eluting systems for new coronary stent designs. Our objective was to analyze the efficacy and safety of new drug-eluting stent models compared with a conventional stent and commercialized drug-eluting stents in an experimental model with healthy porcine coronary arteries. METHODS Sixty stents (conventional stent, new sirolimus-eluting stents: drug-eluting stents 1, 2 and 3; Cypher(®) and Xience(®)) were randomly placed in the coronary arteries of 20 Large White domestic pigs. Angiographic and histomorphometric studies were done 28 days later. RESULTS The stents were implanted at a stent/artery ratio of 1.34±0.15, with no significant differences between groups. The new stents showed less late loss and angiographic restenosis than conventional stents (P=.006 and P<.001, respectively). Histologically, restenosis and neointimal area were lower with all the new platforms than with the conventional stents (P<.001 for each variable), and no differences were found vs the drug-eluting stents on the market. Safety data showed that endothelialization was lower with drug-eluting stents than with conventional stents, except for drug-eluting stent 3 (P=.084). Likewise, inflammation was lower with drug-eluting stent 3 than with other stents. CONCLUSIONS The new drug-eluting stent platforms studied are associated with less restenosis than conventional stents and showed no significant differences in safety or efficacy vs commercialized drug-eluting stents.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

نتایج بالینی پس از آنژیوپلاستی عروق کرونر، بروز حوادث بزرگ قلبی-عروقی و عوارض انواع استنت

Background: Cardiovascular diseases alone have become the leading cause of death worldwide. One of the treatment methods cardiovascular disease is angioplasty. This study aimed to investigate the clinical results after coronary artery angioplasty, based on the incidence of major cardiovascular events with emphasis on stent types. Methods: In this retrospective cross-sectional study, the preval...

متن کامل

Five-year clinical outcomes in patients with diabetes mellitus treated with polymer-free sirolimus- and probucol-eluting stents versus second-generation zotarolimus-eluting stents: a subgroup analysis of a randomized controlled trial

BACKGROUND Improved outcomes in patients with diabetes mellitus undergoing percutaneous coronary intervention remain an unmet clinical need. We assessed the long-term efficacy and safety of novel polymer-free sirolimus- and probucol-eluting stent in diabetic patients enrolled in intracoronary stenting and angiographic results: test efficacy of sirolimus- and probucol-eluting versus zotarolimus-...

متن کامل

Long-term effectiveness and safety of sirolimus drug-eluting stents

The root cause of coronary artery disease is atherosclerosis, ie, intraluminal narrowing (stenosis) of the arteries that supply blood to tissues of the heart. The introduction of the drug-eluting stent over the past decade has revolutionized the field of interventional cardiology. It is used extensively in clinical practice for the treatment of coronary artery disease. The first drug-eluting st...

متن کامل

Angiographic and clinical comparison of novel Orsiro Hybrid sirolimus-eluting stents and Resolute Integrity zotarolimus-eluting stents in all-comers with coronary artery disease (ORIENT trial): study protocol for a randomized controlled trial

BACKGROUND The Orsiro Hybrid sirolimus-eluting stent is a newly developed third-generation drug-eluting stent, featuring a unique dual-polymer mix. An active bioabsorbable polymer delivers the anti-proliferative drug, sirolimus, via controlled release, while a passive biocompatible polymeric coating shields the metallic strut from surrounding tissue, preventing interaction. To date, the Orsiro ...

متن کامل

A randomized, prospective, intercontinental evaluation of a bioresorbable polymer sirolimus-eluting coronary stent system: the CENTURY II (Clinical Evaluation of New Terumo Drug-Eluting Coronary Stent System in the Treatment of Patients with Coronary Artery Disease) trial

AIM The aim of this study was to establish safety and efficacy of a new sirolimus-eluting stent with bioresorbable polymer, Ultimaster (BP-SES). Sirolimus-eluting stent with bioresorbable polymer was compared with everolimus-eluting, permanent polymer, Xience stent (PP-EES) in the frame of a CENTURY II clinical trial designed to make global clinical data compliant with regulatory requirements i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 68 12  شماره 

صفحات  -

تاریخ انتشار 2015