Evaluation of the safety of high-frequency chest wall oscillation (HFCWO) therapy in blunt thoracic trauma patients

نویسندگان

  • Casandra A Anderson
  • Cassandra A Palmer
  • Arthur L Ney
  • Brian Becker
  • Steven D Schaffel
  • Robert R Quickel
چکیده

BACKGROUND Airway clearance is frequently needed by patients suffering from blunt chest wall trauma. High Frequency Chest Wall Oscillation (HFCWO) has been shown to be effective in helping to clear secretions from the lungs of patients with cystic fibrosis, bronchiectasis, asthma, primary ciliary dyskinesia, emphysema, COPD, and many others. Chest wall trauma patients are at increased risk for development of pulmonary complications related to airway clearance. These patients frequently have chest tubes, drains, catheters, etc. which could become dislodged during HFCWO. This prospective observational study was conducted to determine if HFCWO treatment, as provided by The Vesttrade mark Airway Clearance System (Hill-Rom, Saint Paul, MN), was safe and well tolerated by these patients. METHODS Twenty-five blunt thoracic trauma patients were entered into the study. These patients were consented. Each patient was prescribed 2, 15 minute HFCWO treatments per day using The Vest(R) Airway Clearance System (Hill-Rom, Inc., St Paul, MN). The Vest(R) system was set to a frequency of 10-12 Hz and a pressure of 2-3 (arbitrary unit). Physiological parameters were measured before, during, and after treatment. Patients were free to refuse or terminate a treatment early for any reason. RESULTS No chest tubes, lines, drains or catheters were dislodged as a result of treatment. One patient with flail chest had a chest tube placed after one treatment due to increasing serous effusion. No treatments were missed and continued without further incident. Post treatment survey showed 76% experienced mild or no pain and more productive cough. Thirty days after discharge there were no deaths or hospital re-admissions. CONCLUSION This study suggests that HFCWO treatment is safe for trauma patients with lung and chest wall injuries. These findings support further work to demonstrate the airway clearance benefits of HFCWO treatment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unusual Presentation of Pulmonary Hematoma after Blunt Chest Wall Trauma

A 25-year-old man was admitted in hospital due to right side hemopneumothorax secondary to car accident. A chest tube was inserted. During the hospitalization days, chest CT scan revealed a 3cmx3 cm oval-shaped density located in the right upper lobe. Since he was in a good general condition, he was discharged from hospital after removal of chest tube and a follow-up chest CT-scan was recommend...

متن کامل

Evaluation of PERSH Criteria to Avoid Unnecessary Chest X-ray in Patients with Blunt Chest Trauma: A Qualitative Study

Background: Chest X-rays (CXRs) are traditionally performed to determine intra-thoracic injuries in all blunt chest trauma patients in Shahid Bahonar hospital in Kerman. As there are some disadvantages upon CXR and radiation exposure, therefore, this study aimed to evaluate the role of CXR in the diagnosis of intra-thoracic injuries caused by any blunt chest trauma. Me...

متن کامل

Instantaneous responses to high-frequency chest wall oscillation in patients with acute pneumonic respiratory failure receiving mechanical ventilation

BACKGROUND Endotracheal intubation and prolonged immobilization of patients receiving mechanical ventilation may reduce expectoration function. High-frequency chest wall oscillation (HFCWO) may ameliorate airway secretion movement; however, the instantaneous changes in patients' cardiopulmonary responses are unknown. Moreover, HFCWO may influence ventilator settings by the vigorous oscillation....

متن کامل

Long-term multicentre randomised controlled study of high frequency chest wall oscillation versus positive expiratory pressure mask in cystic fibrosis.

BACKGROUND Positive expiratory pressure (PEP) is the most commonly used method of airway clearance (AC) in Canada for patients with cystic fibrosis (CF) whereas, in some countries, high frequency chest wall oscillation (HFCWO) is the preferred form of AC. There have been no long-term studies comparing the efficacy of HFCWO and PEP in the CF population. OBJECTIVES To determine the long-term ef...

متن کامل

Pain after Lung Trans - Plant : High - Frequency Chest Wall Oscillation Vs Chest Physiotherapy

Background Chest physiotherapy and high-frequency chest wall oscillation (HFCWO) are routinely used after lung transplant to facilitate removal of secretions. To date, no studies have been done to investigate which therapy is more comfortable and preferred by lung transplant recipients. Patients who have less pain may mobilize secretions, heal, and recover faster. Objectives To compare effects ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of Trauma Management and Outcomes

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2008