INR calibration of Owren-type prothrombin time based on the relationship between PT% and INR utilizing normal plasma samples.

نویسندگان

  • Tomas L Lindahl
  • Nils Egberg
  • Andreas Hillarp
  • Ole R Ødegaard
  • Bror Edlund
  • Jan Svensson
  • Per M Sandset
  • Mats Rånby
چکیده

Prothrombin time (PT) is clinically important and is used to monitor oral anticoagulant therapy. To obtain PT results in international normalized ratio (INR), the current standardization procedure is complex and involves reference reagents. The PT of diluted plasma samples can be determined with a combined thromboplastin (the Owren-type procedure), but not necessarily with a plain thromboplastin (the Quick-type procedure). Owren-type PT procedures can therefore, as an alternative to the INR calibration, be calibrated with diluted normal plasma to give PT results in percent of normal PT activity (PT%). The present study explored if a plasma-based calibration of an Owren-type PT procedure can be used to obtain results in INR. The approach was to establish a relationship between PT% and INR by multi-center analysis of 365 samples from healthy individuals and patients on warfarin treatment. INR values were obtained by manual Quick-type reference procedure and PT% values by various automated Owren-type procedures. A relationship INR = (1/PT% + 0.018)/0.028 was found. A calibration procedure, based on the relationship, was investigated. Calibrators were the median PT of 21 normal plasma at dilutions representing 100%, 50%, 25%, 12.5% and 6.25% of normal PT activity. These were assigned INR values of 1.00, 1.36, 2.07, 3.05 and 6.36. Calibration of various Owren-type assays was repeatedly performed by 5 expert laboratories during 3 consecutive years. The INR values of certain lyophilised or frozen control plasmas were determined. The frozen control plasmas had externally assigned INR values according to WHO guide-lines. Within the laboratory, CV was typically below 3%. No appreciable difference among the results of the different laboratories or the three assay occasions was found. Externally assigned and INR values were essentially identical to those found. These and other results indicated that the calibration procedure was reproducible, precise and accurate. Thus, an Owren-type PT assay can be calibrated with normal plasma samples to give results in INR and the investigated calibration procedure can be proposed for this purpose.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New-Generation Method for Quick and Owren PT

Oral anticoagulant therapy (OAT) calls for continuous control by prothrombin time (PT) test, as the therapeutic range in INR units is very narrow. Warfarin (or coumarin) inhibits coagulation factor synthesis in the liver, but at the same time inactive coagulation factors are formed. The aim here was to measure "active coagulation factors" and inhibition in calibrator kits and patient plasmas by...

متن کامل

A sensitivity comparison of the Quick and Owren prothrombin time methods in oral anticoagulant therapy

Prothrombin time (PT) is the leading test for monitoring oral anticoagulation therapy (OAT). According to the World Health Organization recommendation, International Normalized Ratio (INR) results obtained from the same patient samples with the major PT methods (Quick and Owren) should be the same when the therapeutic range is the same. In our study blood samples were obtained from 207 OAT pati...

متن کامل

Field study of lyophilised plasmas for local prothrombin time calibration in The Netherlands.

AIM To assess the effect of a lyophilised calibrant plasma procedure on the international normalised ratio (INR) and its interlaboratory variation. METHODS INR equivalent values were assigned to five lyophilised plasmas (one from normal donors and four from coumarin treated patients) by a reference laboratory using three calibrated thromboplastin reagents. The calibrant plasmas and five artif...

متن کامل

Effects of the oral, direct thrombin inhibitor dabigatran on five common coagulation assays.

Dabigatran is an oral, reversible thrombin inhibitor that has shown promising results in large clinical trials. Laboratory monitoring is not needed but the effects on common coagulation assays are incompletely known. Dabigatran was added to plasma from healthy subjects in the concentration range 0-1,000 μg/l and analysed using several reagents for activated thromboplastin time (APTT), prothromb...

متن کامل

Evaluation of European Concerted Action on Anticoagulation lyophilized plasmas for INR derivation using the PT/INR line.

The prothrombin time/international normalized ratio (PT/INR) Line method based on 5 certified European Concerted Action on Anticoagulation (ECAA) plasmas provides reliable local INR values without conventional World Health Organization international sensitivity index calibrations. The present study investigated the use of different numbers and types of ECAA calibrant plasmas to derive accurate ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Thrombosis and haemostasis

دوره 91 6  شماره 

صفحات  -

تاریخ انتشار 2004