X iv : a st ro - p h / 05 02 40 0 v 1 2 1 Fe b 20 05 The OH 1612 MHz maser pump rates of stellar , interstellar and post - AGB OH masers .
نویسنده
چکیده
(Pseudo) radiative pumprate of OH 1612MHz masers is defined for a sample of 44 OH/IR sources (infrared sources with OH 1612MHz maser), irrespective of the real maser pumping mechanisms. The correlation between the (pseudo) maser pumprates and the evolutionary status of the maser sources reveals that the radiative pumprates of stellar OH masers are nearly fixed, which agrees with the theoretical prediction for radiatively pumped OH maser. The (pseudo) radiative pumprates of interstellar OH masers are not only very small but also varying broadly over two orders of magnitude, which is argued to be the manifestation of varying number of quiet absorbing OH cloudlets and/or various OH maser pumping mechanisms and/or competitive gain between mainline and 1612MHz OH masers and/or anisotropy of the maser emission. The radiative pumprates of post-AGB OH masers very possibly decrease with increasing IRAS C32 color indices and distribute in an interim region between the stellar and interstellar OH masers in the pumprate-color diagram.
منابع مشابه
2 00 5 The OH 1612 MHz maser pump rates of stellar , interstellar and post - AGB OH masers .
(Pseudo) radiative pumprate of OH 1612MHz masers is defined for a sample of 44 OH/IR sources (infrared sources with OH 1612MHz maser), irrespective of the real maser pumping mechanisms. The correlation between the (pseudo) maser pumprates and the evolutionary status of the maser sources reveals that the radiative pumprates of stellar OH masers are nearly fixed, which agrees with the theoretical...
متن کاملar X iv : a st ro - p h / 04 11 20 1 v 1 8 N ov 2 00 4 Discovery of an OH ( 1720 MHz ) Maser in the LMC
We report the first study of OH(1720 MHz) masers in the LMC in order to probe regions where supernova remnants interact with adjacent molecular clouds. Using the ATCA, we observed four sources in the LMC and detected a single OH(1720 MHz) maser with a flux density of 377 mJy toward 30 Doradus. No main line emission at 1665 or 1667 MHz was detected. The observed OH(1720 MHz) maser emission from ...
متن کاملar X iv : a st ro - p h / 97 12 10 1 v 1 7 D ec 1 99 7 SiO Maser Forest at the Galactic Center
A moderately deep survey of stellar maser sources toward the Galactic center has been made in the SiO J=1-0 v=1 and v=2 transitions (∼ 43 GHz) with the Nobeyama 45-m telescope of a beam size of about 40. At the Galactic center (Sgr A*), 7 (4 new) SiO maser sources were detected in one beam. In order to investigate the spatial distribution of SiO maser sources, we have also observed the offset p...
متن کاملSearch for radiative pumping lines of OH masers : I . The 34 . 6 μ m absorption line towards 1612 MHz OH maser sources . ⋆
The 1612 MHz hydroxyl maser in circumstellar envelopes has long been thought to be pumped by 34.6 µm photons. Only recently, the Infrared Space Observatory has made possible spectroscopic observations which enable the direct confirmation of this pumping mechanism in a few cases. To look for the presence of this pumping line, we have searched the Infrared Space Observatory Data Archive and found...
متن کاملar X iv : a st ro - p h / 06 02 21 0 v 1 9 F eb 2 00 6 GBT Observations of IC 443 : the Nature of OH ( 1720 MHz )
We present results of spectral line observations of the ground state transitions of hydroxyl(OH) toward supernova remnant IC 443 carried out with the Green Bank Telescope. At a spatial resolution of 7. ′ 2 we detect weak, extended OH(1720 MHz) maser emission with OH(1667/5,1612 MHz) absorption along the southern extent of the remnant, where no bright compact maser sources have been observed pre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005