Aneurysm ostium angle: a predictor of the need for stent as assistance for endovascular aneurysm coiling in internal carotid artery sidewall aneurysms.

نویسندگان

  • R Yasuda
  • A Arat
  • C M Strother
  • B Aagaard-Kienitz
  • D Niemann
  • A Mohamed
  • K Royalty
  • K Pulfer
  • W Taki
  • M E Mawad
چکیده

BACKGROUND AND PURPOSE There is no satisfactory parameter that can predict the need for assistant devices for endovascular aneurysm coiling. Our aim was to evaluate the utility of MOA as a predictor of the need for stent-assisted coiling in ICA sidewall aneurysms. MATERIALS AND METHODS From a retrospective review of an internal data base, 55 consecutive ICA sidewall aneurysms were identified. Thirty-two of the aneurysms were treated by using endovascular techniques. Because 23 of the 55 aneurysms were either untreated or clipped, 3 experienced interventionalists reviewed the 3D images of these aneurysms and then made a decision as to whether stent-assisted coiling would have been required. Thirty-one of the 55 aneurysms would have required stent-assisted coiling, while 24 would not. Neck width, DNR, AR, and MOA were obtained from each aneurysm by using prototype software. These parameters were then correlated with the requirement of stent-assisted coiling. RESULTS MOA and neck width of aneurysms requiring stent-assisted coiling were significantly larger than those not requiring stent-assisted coiling (P < .001 and <0.001, respectively). Although the DNR and AR of aneurysms requiring stent-assisted coiling were smaller than those not requiring it, the difference was not significant (P = .22 and 0.12, respectively). ROC analysis revealed that MOA was the parameter that best correlated with the need for stent-assisted coiling. Inclusion of MOA with the rest of the parameters significantly increased the predictive performance regarding the need for stent-assisted coiling (P = .005). CONCLUSIONS In this small study, MOA was a useful parameter to predict the need for stent-assisted coiling in ICA sidewall aneurysms. Further prospective study of this parameter for aneurysms at multiple locations is required to determine its ultimate value.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful endovascular coiling of a ruptured internal iliac artery aneurysm: a case report

Ruptured internal iliac artery aneurysms (IIAA) are extremely rare, and the repair can be challenging. This case reports described an 83-year-old patient who presented at our Emergency Department with acute abdominal pain based on a ruptured IIAA. He refused open repair and only wanted to be treated as minimally invasive as possible. Therefore endovascular embolization of the IIAA was performed...

متن کامل

The Treatment of Large and Giant Paraclinoid Internal Carotid Artery Aneurysms

Paraclinoid internal carotid artery aneurysms originate from the internal carotid artery between the distal dural ring and the posterior communicating artery. Surgical treatment of these aneurysms is technically challenging because of the surrounding neurovascular structures. There are several ways to treat these lesions: direct clipping with retrograde suction decompression, endovascular coili...

متن کامل

Enlarged Parent Artery Lumen at Aneurysmal-Neck Segment in Wide-Necked Distal Internal Carotid Artery Aneurysms

PURPOSE Hypothesizing that the parent artery (PA) diameter of the aneurysm-neck segment is larger than those of normal segments, especially in wide-necked aneurysm cases, we conducted 3D angiographic analyses in wide-necked aneurysm cases focusing on the luminal morphologic change of the PA. MATERIALS AND METHODS Under the approval of local IRB, we enrolled 26 patients with distal internal ca...

متن کامل

Jailing Technique Using a Catheter-based Open-cell Stent System in Internal Carotid Artery Sidewall Aneurysms Unfeasible to Simple Coiling

OBJECTIVE An open cell stent system may offer better apposition of cell struts to vessel wall than a closed cell stent system in acute vasculature. The purpose of this study was to evaluate the feasibility of coiling using the jailing technique with the Neuroform EZ stent system. METHODS The jailing technique using the open-cell stent system of the Neuroform EZ stent was planned in 22 consecu...

متن کامل

Clinical Analysis of Giant Intracranial Aneurysms with Endovascular Embolization

OBJECTIVE The purpose of this study was to perform a clinical analysis of nine patients with giant aneurysms managed with endovascular embolization. METHODS From March 2000 to September 2009, nine cases of giant intracranial aneurysms were treated (five unruptured and four ruptured). The nine patients included two males and seven females who were 47 to 72 years old (mean, 59.2 years old). The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 32 7  شماره 

صفحات  -

تاریخ انتشار 2011