Impact of adding a filter for protection from toxic inhalational compounds to the ventilation circuit of mechanically ventilated patients
نویسندگان
چکیده
BACKGROUND Standard-issue Chemical-Biological-Radio-Nuclear (CBRN) gasmasks, as used for protection from non-conventional warfare agents or toxic industrial compounds, cannot be used by ventilated patients, leaving them exposed to toxic agents inhaled via their ventilators. This study was conducted to determine the safety of a CBRN filter added to the patient circuit of a ventilator, as a method for affording inhalational protection to ventilated patients. METHODS A Landrace pig was ventilated sequentially with 3 types of ventilators according to 17 different ventilation protocols, with and without a CBRN filters added in-line to the ventilation tubing for each protocol. For each protocol, physiological parameters, including oxygen saturation, inspired CO2, end tidal CO2, inspired oxygen, respiratory rate, and pulse rate, as well as airflow parameters including peak inspiratory pressure, positive end expiratory pressure and tidal volume were measured. The impact on the ventilator's trigger/sensitivity function was evaluated in vitro using a Michigan test lung. RESULTS On average, the addition of the CBRN filter resulted in a 16 ml (5 %) decrease (range 0-50 ml) in the tidal volume, a 1.7 cm H2O (10 %) decrease (range 1-3 cm H2O) in the peak inspiratory pressure, and a 0.1 cm H2O (3 %) decrease (range 0-1 cm H2O) in the positive end expiratory pressure delivered to the animal. Some ventilators compensated for these airflow changes while others did not, depending on the design of the ventilator's pressure/flow sensing mechanism. Significant rebreathing occurred when the filter was positioned directly on the animal's endotracheal tube, but not when positioned on the air outflow port of the ventilator. In vitro measurements showed that the addition of the CBRN filter added a mean pressure gradient of 0.45 cm H2O to the trigger/sensitivity function of the system. CONCLUSIONS In-line addition of a CBRN filter to ventilation tubing is a feasible strategy for affording inhalational protection to ventilated patients.
منابع مشابه
Impact of Oral Clonidine on Duration of Opioid and Benzodiazepine Use in Mechanically Ventilated Children: A Randomized, Double-Blind, Placebo-Controlled Study
Objective: Long term use of opioids and benzodiazepines are associated with important untoward effects. The α2 adrenergic agonist clonidine has sedative effects. Our goal was to study clonidine addition to total doses of fentanyl and midazolam and duration of ventilation in pediatric ICU (PICU). Methods: This randomized, double-blind, placebo-controlled trial was conducted in PICU of Mofi...
متن کاملThe effect of Therapeutic Touch on Physiological Variables of Mechanically Ventilated Patients in Intensive Care Units
Background: Underlying diseases and aggressive procedures, such as different types of surgery and care, for patients with critical conditions in intensive care units (ICU) may be associated with physiological disorders. Objectives: This study intended to determine the effect of therapeutic touch on physiological variables of patients undergoing mechanical ventilation in ICU. Methods: This...
متن کاملImpact of Oral Clonidine on Duration of Opioid and Benzodiazepine Use in Mechanically Ventilated Children: A Randomized, Double-Blind, Placebo-Controlled Study
Objective: Long term use of opioids and benzodiazepines are associated with important untoward effects. The α2 adrenergic agonist clonidine has sedative effects. Our goal was to study clonidine addition to total doses of fentanyl and midazolam and duration of ventilation in pediatric ICU (PICU). Methods: This randomized, double-blind, placebo-controlled trial was conducted in PICU of Mofi...
متن کاملA Randomized Placebo-controlled Trial of Clonidine Impact on Sedation of Mechanically Ventilated ICU Patients
Clonidine has sedative and analgesic properties. Randomized studies examining these properties in mechanically ventilated ICU patients are scarce. This study was designed to assess the impact of clonidine on sedative agent use in mechanically ventilated patients.In a prospective, randomized, double blind, placebo-controlled study in a general ICU of a university medical center in Tehran, Iran, ...
متن کاملA Randomized Placebo-controlled Trial of Clonidine Impact on Sedation of Mechanically Ventilated ICU Patients
Clonidine has sedative and analgesic properties. Randomized studies examining these properties in mechanically ventilated ICU patients are scarce. This study was designed to assess the impact of clonidine on sedative agent use in mechanically ventilated patients.In a prospective, randomized, double blind, placebo-controlled study in a general ICU of a university medical center in Tehran, Iran, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2 شماره
صفحات -
تاریخ انتشار 2016