EEG noise cancellation by a subspace method based on wavelet decomposition.

نویسندگان

  • Hannu Olkkonen
  • Peitsa Pesola
  • Juuso Olkkonen
  • Antti Valjakka
  • Leena Tuomisto
چکیده

BACKGROUND Noise reduction techniques play an essential role in EEG signal processing applications. A variety of methods are currently in use, including those based on linear filtering and adaptive noise cancellation, as well as subspace-based methods using singular value decomposition (SVD). SVD offers a robust method to decompose the data matrix into signal and noise subspaces. However, the SVD algorithm is characterized by high computational complexity, which restricts its use in real time EEG signal analysis. MATERIAL/METHODS In this work we applied a wavelet transform to decompose the EEG signal into parallel subsignals. Noise was cancelled using the SVD-based method for each subsignal, and the noiseless EEG was reconstructed by using an inverse wavelet transform. EEGs were recorded in freely behaving rats from two different sites of the brain: 1). the hilar region of the dentate gyrus of the hippocampus, 2). the frontal cortex, with the electrode tip located in the vicinity of the epipial neocortical surface. RESULTS Our noise suppression method had the most obvious effect on the EEG frequency spectrum, where random noise was considerably diminished. In the time domain, the reconstructed waveform closely resembled the original EEG signal, but it could clearly be seen that most of the transient spikes had been removed. CONCLUSIONS The present method offers remarkable computational savings and is especially well adapted for the analysis of highly dynamic EEGs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Active Noise Cancellation using Online Wavelet Based Control System: Numerical and Experimental Study

Reaction wheels (RWs) used for attitude control of space vehicle systems usually encounter with undesired wide band noises. These noises which significantly affect the performance of regulator controller must tune the review or review rate of RWs. According to wide frequency band of noises in RWs the common approaches of noise cancellation cannot conveniently reduce the effects of the noise. Th...

متن کامل

Feature Extraction of Visual Evoked Potentials Using Wavelet Transform and Singular Value Decomposition

Introduction: Brain visual evoked potential (VEP) signals are commonly known to be accompanied by high levels of background noise typically from the spontaneous background brain activity of electroencephalography (EEG) signals. Material and Methods: A model based on dyadic filter bank, discrete wavelet transform (DWT), and singular value decomposition (SVD) was developed to analyze the raw data...

متن کامل

A Novel Noise Reduction Method Based on Subspace Division

This article presents a new subspace-based technique for reducing the noise of signals in time-series. In the proposed approach, the signal is initially represented as a data matrix. Then using Singular Value Decomposition (SVD), noisy data matrix is divided into signal subspace and noise subspace. In this subspace division, each derivative of the singular values with respect to rank order is u...

متن کامل

A Novel Noise Reduction Method Based on Subspace Division

This article presents a new subspace-based technique for reducing the noise of signals in time-series. In the proposed approach, the signal is initially represented as a data matrix. Then using Singular Value Decomposition (SVD), noisy data matrix is divided into signal subspace and noise subspace. In this subspace division, each derivative of the singular values with respect to rank order is u...

متن کامل

EEG Artifact Removal System for Depression Using a Hybrid Denoising Approach

Introduction: Clinicians use several computer-aided diagnostic systems for depression to authorize their diagnosis. An electroencephalogram  (EEG) may be used as an objective tool for early diagnosis of depression and controlling it from reaching a severe and permanent state. However, artifact contamination reduces the accuracy in EEG signal processing systems. Methods: This work proposes a no...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical science monitor : international medical journal of experimental and clinical research

دوره 8 11  شماره 

صفحات  -

تاریخ انتشار 2002