Acute Changes in Central Corneal Thickness According to Experimental Adjustment of Intraocular Pressure in Normal Canine Eyes

نویسندگان

  • Young-Woo PARK
  • Man-Bok JEONG
  • Eui Ri LEE
  • Yesran LEE
  • Jae-Sang AHN
  • Soo-Hyun KIM
  • Kangmoon SEO
چکیده

Central corneal thickness (CCT) can be a promising source of glaucoma monitoring and diagnosis. This study evaluated changes in CCT according to experimental adjustment of intraocular pressure (IOP) in canine eyes. To adjust and measure IOP, each eye was cannulated with two 26-gauge needles under inhalant anesthesia. One needle was connected to a pressure transducer, and the other was connected to an adjustable bag of physiologic saline. IOP was stepwise increased from 10 mmHg to 70 mmHg in 10 mmHg increments (Group T). IOP was maintained at 15 mmHg (Group C15), 30 mmHg (Group C30), 45 mmHg (Group C45), 60 mmHg (Group C60) and 75 mmHg (Group C75) during the experiment. CCT was measured with an ultrasonic pachymeter every 10 min after cannulation. There was a significant difference in the effect of time on CCT (P<0.001) and difference in CCT (dCCT; P<0.001) between groups. The CCT of group C15 remained constant during the experiment. However, group T showed an initial decrease and then an increase after passing the lowest point. Group C30 showed decreasing values for 30 min, after which the values remained constant. The values in Group C45 showed no changes for 40 min and then increased. The values in group C60 showed no change for 20 min and then increased. Group C75 showed a steady increase. In conclusion, the CCT showed two core changes according to increased IOP. This study provides essential basic data to enable further investigation into the association of IOP and CCT in dogs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea

Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...

متن کامل

بررسی ارتباط بین ضخامت مرکز قرنیه و میزان فشار داخل چشمی اندازه گیری شده با تونومتر گلدمن

To determine the effect of central corneal thickness (CCT) on measured intraocular pressure (IOP) and evaluating the relationship between them in each of the groups of patients including: Normal subjects, ocular hypertension patients and patients with primary open angle glucoma (POAG). Correlation between intraocular pressure (Measured by Goldman applanation tonometer) and central corneal thick...

متن کامل

Short-term effects and safety of an acute increase of intraocular pressure after intravitreal bevacizumab injection on corneal endothelial cells

BACKGROUND The purpose of this study is to evaluate short-term effects and safety of an acute increase of intraocular pressure (IOP) after single-dose intravitreal bevacizumab injection on corneal endothelial cells and central corneal thickness. METHODS Forty-two patients who underwent intravitreal injection of 2.5 mg/0.1 ml bevacizumab because of central serous chorioretinopathy or diabetic ...

متن کامل

Longitudinal effect of topical antiglaucoma medications on central corneal thickness.

BACKGROUND To determine the change in central corneal thickness over time and whether the use of long-term topical antiglaucoma medications influences central corneal thickness. DESIGN Case control study with retrospective and prospective data collection. PARTICIPANTS One hundred eighty-seven eyes of 187 glaucoma patients (mean follow up 6.92 ± 1.67 years) being treated with topical antigla...

متن کامل

Changes in corneal biomechanics and applanation tonometry with induced corneal swelling.

PURPOSE To investigate the changes in Goldmann applanation tonometry (GAT) and Ocular Response Analyzer (ORA) measurements with corneal edema induced by contact lenses. METHODS Twenty-five healthy, normal subjects (age, 23 ± 2 years) had central corneal radius (CCR), ORA, GAT, and central corneal thickness (CCT) measurements performed in both eyes before a thick, soft hydrogel contact lens wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 75  شماره 

صفحات  -

تاریخ انتشار 2013