The effects of pleural fluid drainage on respiratory function in mechanically ventilated patients after cardiac surgery
نویسندگان
چکیده
BACKGROUND Pleural effusions occur commonly after cardiac surgery and the effects of drainage on gas exchange in this population are not well established. We examined pulmonary function indices following drainage of pleural effusions in cardiac surgery patients. METHODS We performed a retrospective study examining the effects of pleural fluid drainage on the lung function indices of patients recovering from cardiac surgery requiring mechanical ventilation for more than 7 days. We specifically analysed patients who had pleural fluid removed via an intercostal tube (ICT: drain group) compared with those of a control group (no effusion, no ICT). RESULTS In the drain group, 52 ICTs were sited in 45 patients. The mean (SD) volume of fluid drained was 1180 (634) mL. Indices of oxygenation were significantly worse in the drain group compared with controls prior to drainage. The arterial oxygen tension (PaO2)/fractional inspired oxygen (FiO2) (P/F) ratio improved on day 1 after ICT placement (mean (SD), day 0: 31.01 (8.92) vs 37.18 (10.7); p<0.05) and both the P/F ratio and oxygenation index (OI: kPa/cm H2O=PaO2/mean airway pressure×FiO2) demonstrated sustained improvement to day 5 (P/F day 5: 39.85 (12.8); OI day 0: 2.88 (1.10) vs day 5: 4.06 (1.73); both p<0.01). The drain group patients were more likely to have an improved mode of ventilation on day 1 compared with controls (p=0.028). CONCLUSIONS Pleural effusion after cardiac surgery may impair oxygenation. Drainage of pleural fluid is associated with a rapid and sustained improvement in oxygenation.
منابع مشابه
Intrapleural Fibrinolysis in Post-tubercular Loculated Pleural Effusions at a Tertiary-Care Respiratory Center: An Uncontrolled Blinded Before-After Intervention Study
Background: Tuberculous, parapneumonic and traumatic loculated pleural-effusions pose therapeutic challenges due to resultant pleural-thickening and compromised lung-function for life. Tuberculosis is widely prevalent in developing countries, necessitating appropriate, effective, and economical treatment for loculated pleural-effusion to reduce the burden and sequelae. <s...
متن کاملDrainage of pleural effusion improves diaphragmatic function in mechanically ventilated patients.
BACKGROUND Pleural effusion adversely affects the pressuregenerating capacity of the diaphragm. It uncouples the lung and chest wall, which may result in diaphragmatic dysfunction. Information on the effects of effusion drainage on diaphragmatic function is limited, but several studies report relief of dyspnoea after drainage, which was attributed to improved diaphragmatic mechanics, even if th...
متن کاملThe respiratory change in preejection period: a new method to predict fluid responsiveness.
The accuracy and clinical utility of preload indexes as bedside indicators of fluid responsiveness in patients after cardiac surgery is controversial. This study evaluates whether respiratory changes (Delta) in the preejection period (PEP; DeltaPEP) predict fluid responsiveness in mechanically ventilated patients. Sixteen postcoronary artery bypass surgery patients, deeply sedated under mechani...
متن کاملConservative Management in a Ventilated Preterm Neonate with Pneumopericardium, Pleural Effusion, and Pulmonary Collapse: A Case Report
Background: Neonatal pneumopericardium (PPC) is a rare clinical condition usually associated with other air leak syndromes. It increases morbidity and mortality due to cardiac tamponade. Case report: A preterm male neonate weighing 1260 g was born with the gestational age of 28 weeks. Cardiopulmonary resuscitation was routinely performed without any medical therapy. The newborn was transferred ...
متن کاملEvaluation of the Effect of Nebulized N-Acetylcysteine on Respiratory Secretions in Mechanically Ventilated Patients: Randomized Clinical Trial
Background: The purpose of our study was to evaluate an inexpensive and available method to reduce mucous impactions in mechanically ventilated patients.Methods: This randomized clinical trial was conducted on 40 mechanically ventilated patients aged 15-90 years. The patients were randomly allocated into two arms; 20 cases and 20 controls. The cases received N-acetylcysteine via their nebulizer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2 شماره
صفحات -