Variant Callers for Next-Generation Sequencing Data: A Comparison Study

نویسندگان

  • Xiangtao Liu
  • Shizhong Han
  • Zuoheng Wang
  • Joel Gelernter
  • Bao-Zhu Yang
چکیده

Next generation sequencing (NGS) has been leading the genetic study of human disease into an era of unprecedented productivity. Many bioinformatics pipelines have been developed to call variants from NGS data. The performance of these pipelines depends crucially on the variant caller used and on the calling strategies implemented. We studied the performance of four prevailing callers, SAMtools, GATK, glftools and Atlas2, using single-sample and multiple-sample variant-calling strategies. Using the same aligner, BWA, we built four single-sample and three multiple-sample calling pipelines and applied the pipelines to whole exome sequencing data taken from 20 individuals. We obtained genotypes generated by Illumina Infinium HumanExome v1.1 Beadchip for validation analysis and then used Sanger sequencing as a "gold-standard" method to resolve discrepancies for selected regions of high discordance. Finally, we compared the sensitivity of three of the single-sample calling pipelines using known simulated whole genome sequence data as a gold standard. Overall, for single-sample calling, the called variants were highly consistent across callers and the pairwise overlapping rate was about 0.9. Compared with other callers, GATK had the highest rediscovery rate (0.9969) and specificity (0.99996), and the Ti/Tv ratio out of GATK was closest to the expected value of 3.02. Multiple-sample calling increased the sensitivity. Results from the simulated data suggested that GATK outperformed SAMtools and glfSingle in sensitivity, especially for low coverage data. Further, for the selected discrepant regions evaluated by Sanger sequencing, variant genotypes called by exome sequencing versus the exome array were more accurate, although the average variant sensitivity and overall genotype consistency rate were as high as 95.87% and 99.82%, respectively. In conclusion, GATK showed several advantages over other variant callers for general purpose NGS analyses. The GATK pipelines we developed perform very well.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Nine Somatic Variant Callers for Detection of Somatic Mutations in Exome and Targeted Deep Sequencing Data

Next generation sequencing is extensively applied to catalogue somatic mutations in cancer, in research settings and increasingly in clinical settings for molecular diagnostics, guiding therapy decisions. Somatic variant callers perform paired comparisons of sequencing data from cancer tissue and matched normal tissue in order to detect somatic mutations. The advent of many new somatic variant ...

متن کامل

Systematic comparison of variant calling pipelines using gold standard personal exome variants

The success of clinical genomics using next generation sequencing (NGS) requires the accurate and consistent identification of personal genome variants. Assorted variant calling methods have been developed, which show low concordance between their calls. Hence, a systematic comparison of the variant callers could give important guidance to NGS-based clinical genomics. Recently, a set of high-co...

متن کامل

A review of somatic single nucleotide variant calling algorithms for next-generation sequencing data

Detection of somatic mutations holds great potential in cancer treatment and has been a very active research field in the past few years, especially since the breakthrough of the next-generation sequencing technology. A collection of variant calling pipelines have been developed with different underlying models, filters, input data requirements, and targeted applications. This review aims to en...

متن کامل

In-depth comparison of somatic point mutation callers based on different tumor next-generation sequencing depth data

Four popular somatic single nucleotide variant (SNV) calling methods (Varscan, SomaticSniper, Strelka and MuTect2) were carefully evaluated on the real whole exome sequencing (WES, depth of ~50X) and ultra-deep targeted sequencing (UDT-Seq, depth of ~370X) data. The four tools returned poor consensus on candidates (only 20% of calls were with multiple hits by the callers). For both WES and UDT-...

متن کامل

SeqMule: automated pipeline for analysis of human exome/genome sequencing data

Next-generation sequencing (NGS) technology has greatly helped us identify disease-contributory variants for Mendelian diseases. However, users are often faced with issues such as software compatibility, complicated configuration, and no access to high-performance computing facility. Discrepancies exist among aligners and variant callers. We developed a computational pipeline, SeqMule, to perfo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013