A Range Finder by Using a Rotary Cubic Mirror
نویسندگان
چکیده
The slit light scanning method is a conventional method of range finder. But according to this method, it is impossible to measure the three dimensional shape when the object is too large, because camera is fixed against the observation field. In this paper, we propose a new active range finder with a rotary cubic mirror to solve these problems. In this sensing system, slit light and view of camera are moved to the same direction simultaneously by using a rotary cubic mirror. This method is able to obtain the slit light image which dose not include distortion. On the other hand in the proposed sensing system, the image of slit is projected on near the center of the image plane all the time by moving the slit light and the view of camera simultaneously. The experiments were performed to demonstrate the efficacy of this sensor by using this system. As a result, the proposed method can measure the three dimensional position of the object and effectiveness was shown. becomes wide because view of camera is moved by revolving motor. And slit light moves with view of camera to same direction simultaneously, so image of slit is projected near the center of image plane all the time. But this system has some problems. It will become complex system composition because it uses two motors. And to operate the two motor a t the same time together, strict calibration is in need. We propose a new active range finder with simple system component, and no need a strict calibration to move slit light and view of camera simultaneously. This sensor uses swinging mirror that has a cubic shape. This mirror is located between CCD camera and slit light projector. The two units are opposite from each other. Thus, only swinging cubic mirror can realize to move slit light and view of camera simultaneously to the same direction, as a result, there is no need strict calibration. In this paper, we describe the principle of measurement, system component, calculation of 3D position, and results of experiment to verify the efficiency of this method.
منابع مشابه
Experimental Study of a Flash-lamp Pumped Passively Q-Switched Nd:YAG Laser Using Cr4+:YAG Saturable Absorber
This paper deals with the experimental results of a xenon flash-lamp pumped passively Q-switched Nd:YAG laser using Cr4+:YAG saturable absorber. The need of a laser cavity to be integrated into a time-of-flight laser range finder is of great interest as an experimental investigation of several laser resonators. Two types of laser resonator, with different lengths, have been studied: the flat-fl...
متن کاملA Fully Integrated Range-Finder Based on the Line-Stripe Method
In this paper, an imaging chip for acquiring range information using by 0.35 μm CMOS technology and 5V power supply has been described. The system can extract range information without any mechanical movement and all the signal processing is done on the chip. All of the image sensors and mixed-signal processors are integrated in the chip. The design range is 1.5m-10m with 18 scales.
متن کاملUnified Pulsed Laser Range Finder and Velocimeter using Ultra-Fast Time-To-Digital Converter
In this paper, we present a high accuracy laser range finder and velocimeter using ultra-fast time-to-digital converter (TDC). The system operation is based on the measuring the round-trip time of a narrow laser pulse. A low-dark current high-speed PIN photodiode is used to detect the triggered laser beam and to produce start signal. The pulsed laser diode generates 45W optical power at 30ns du...
متن کاملMaximum Maintainability of Complex Systems via Modulation Based on DSM and Module Layout.Case Study:Laser Range Finder
The present paper aims to investigate the effects of modularity and the layout of subsystems and parts of a complex system on its maintainability. For this purpose, four objective functions have been considered simultaneously: I) maximizing the level of accordance between system design and optimum modularity design,II) maximizing the level of accessibility and the maintenance space required,III...
متن کاملConvectional hydrothermal synthesis of high-purity pesudo-cubic BaTi0.09Nb0.01O3 nanocrystals in rotary autoclave
Nano-sized BaTiO3 powders with particular Nb concentrations were prepared by Rotary- Hydrothermal (RH) method. Hydrothermal method was used at 180 °C for 5 hours with new Ti pressure and the teflon vessel was rotated at a speed of 160 rpm during the hydrothermal reaction. New hydrothermal method was used instead of previous solid state reaction for the system BaTiO3±Nb<sub...