Towards a standardization of thrombin generation assessment: The influence of tissue factor, platelets and phospholipids concentration on the normal values of Thrombogram-Thrombinoscope assay

نویسندگان

  • Grigoris T Gerotziafas
  • François Depasse
  • Joël Busson
  • Lena Leflem
  • Ismail Elalamy
  • Meyer M Samama
چکیده

BACKGROUND Thrombin generation assay was developed several years ago to mimic physiological coagulation mechanisms but it had important limitations. Thrombogram-Thrombinoscope assay using a fluorogenic substrate, allows obtaining thrombin generation curves in non-defibrinated platelet rich plasma (PRP) in a fully automated manner. METHODS We standardised the methodology of Thrombogram-Thrombinoscope and we evaluated the precision of thrombin generation parameters (lag-time, maximum concentration of thrombin [Cmax], time required to reach Cmax [Tmax] and endogenous thrombin potential ETP) using different concentrations of recombinant human tissue factor, platelets or phospholipids. Normal values of thrombin generation assay were established in optimal experimental conditions. RESULTS In the presence of low TF concentrations (final dilution of thromboplastin in plasma: 1/1000-1/2000) the Thrombogram assay showed intra-assay and inter-assay coefficients of variation lower than 9%. Thrombin generation parameters showed an important inter-individual variability and the coefficients of variation ranged from 18% to 50%. In PRP the lag-time, Cmax and Tmax but not the ETP, were influenced by TF concentration. Thrombin generation parameters were not influenced by variations of platelet concentration from 50 x 10(9)/l to 400 x 10(9)/l. The addition of synthetic procoagulant phospholipids in PPP strongly influenced all the parameters of thrombogram. For all the parameters of thrombogram a threshold effect was observed in the presence of phospholipid concentrations equal or higher to 4 microM. In frozen-thawed PRP the lag-time and the Tmax were significantly reduced and the Cmax was increased compared to the fresh PRP, but the ETP, the intra assay and the inter-assay coefficients of variation were similar in both test-systems. CONCLUSION Thrombogram-Thrombinoscope assay performed in fresh or in frozen-thawed PRP has an acceptable precision, with low inter-assay and intra-assay coefficient of variations. The concentration of TF is determinant for the normal values of the studied parameters of thrombin generation. When the assay is performed in PPP, thrombin generation parameters are influenced by the concentration of procoagulant synthetic phospholipids. The optimal experimental conditions were obtained in the presence of 1/1000 final dilution of thromboplastin, a platelet count higher than 50 x 10(9)/l and a synthetic phospholipid concentration higher than 4 microM.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ex vivo coagulation test on tissue factor-expressing cells with a calibrated automated thrombogram.

A calibrated automated thrombogram is not affected by the turbidity of platelet and cell preparations because the measurement is based on fluorescence. To examine conditions that mimic the physiological state, we investigated thrombograms that show thrombin generation on tissue factor (TF)-bearing cells. An increase in the number of J82 cells did not affect the endogenous thrombin potential (ET...

متن کامل

Whole-blood thrombin generation monitored with a calibrated automated thrombogram-based assay.

BACKGROUND The calibrated automated thrombogram (CAT) assay in plasma is a versatile tool to investigate patients with hypo- or hypercoagulable phenotypes. The objective was to make this method applicable for whole blood measurements. METHODS Thin-layer technology and the use of a rhodamine 110-based thrombin substrate appear to be essential for a reliable thrombin generation (TG) assay in wh...

متن کامل

The effect of corn trypsin inhibitor, anti-tissue factor pathway inhibitor antibodies and phospholipids on microvesicle-associated thrombin generation in patients with pancreatic cancer and healthy controls

Circulating microvesicles (MVs) are suggested to be important contributors to cancer-associated thrombosis due to the presence of surface-bound procoagulant molecules like tissue factor (TF) and phosphatidylserine (PS). Pancreatic cancer is considered to be one of the most prothrombotic malignancies. The aim of this study was to describe the impact of analytical variables on MV-associated throm...

متن کامل

Reliability of thrombin generation assay on frozen-thawed platelet-rich plasma: a reply.

To the Editor: We read with interest the comments of Lippi et al (1 ) who questioned the reproducibility and difficulty of standardization when we (2 ) used platelet-rich plasma (PRP) in the thrombin generation assay (TGA). We evaluated the use of TGA to identify patients needing further specific thrombophilic risk factor testing (2 ). For this, we used frozen-thawed (ftPRP). PRP was obtained b...

متن کامل

Efficacy of a New Autologus Platelet Gel: in Vitro Study

Abstract Background Autologus platelet gel is easy to prepare and is relatively low cost. The aim of this study was to prepare and evaluate in vitro efficacy of autologus platelet gel. Materials and Methods In this experimental study, platelet concentrate and platelet poor plasma were prepared with aphaeresis method. Thrombin was prepared by mixing the plasma with calcium. Thrombin activity...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Thrombosis Journal

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2005