Performance of Three LED-Based Fluorescence Microscopy Systems for Detection of Tuberculosis in Uganda

نویسندگان

  • Heidi Albert
  • Yukari Manabe
  • George Lukyamuzi
  • Patrick Ademun
  • Sheena Mukkada
  • Barnabas Nyesiga
  • Moses Joloba
  • C. N. Paramasivan
  • Mark D. Perkins
چکیده

BACKGROUND Direct smear microscopy using Ziehl-Neelsen (ZN) staining is the mainstay of tuberculosis (TB) diagnosis in most high burden countries, but is limited by low sensitivity in routine practice, particularly in high human immunodeficiency virus (HIV) prevalence settings. METHODS We compared the performance of three commercial light emitting diode (LED)-based microscopy systems (Primostar™ iLED, Lumin™ and AFTER®) for fluorescent detection of Mycobacterium tuberculosis with ZN microscopy on slides prepared from sputum of TB suspects. Examination time for LED-based fluorescent microscopy (LED FM) and ZN slides was also compared, and a qualitative user appraisal of the LED FM systems was carried out. RESULTS LED FM was between 5.6 and 9.4% more sensitive than ZN microscopy, although the difference was not statistically significant. There was no significant difference in the sensitivity or specificity of the three LED FM systems, although the specificity of Fraen AFTER was somewhat lower than the other LED FM methods. Examination time for LED FM was 2 and 4 times less than for ZN microscopy. LED FM was highly acceptable to Ugandan technologists, although differences in operational performance of the three systems were reported. CONCLUSIONS LED FM compares favourably with ZN microscopy, with equivalent specificity and a modest increase in sensitivity. Screening of slides was substantially quicker using LED FM than ZN, and LED FM was rated highly by laboratory technologists. Available commercial systems have different operational characteristics which should be considered prior to programmatic implementation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Operational Implementation of LED Fluorescence Microscopy in Screening Tuberculosis Suspects in an Urban HIV Clinic in Uganda

BACKGROUND Light emitting diode (LED) fluorescence microscopy (FM) is an affordable, technology targeted for use in resource-limited settings and recommended for widespread roll-out by the World Health Organization (WHO). We sought to compare the operational performance of three LED FM methods compared to light microscopy in a cohort of HIV-positive tuberculosis (TB) suspects at an urban clinic...

متن کامل

Performance of LED-Based Fluorescence Microscopy to Diagnose Tuberculosis in a Peripheral Health Centre in Nairobi

BACKGROUND Sputum microscopy is the only tuberculosis (TB) diagnostic available at peripheral levels of care in resource limited countries. Its sensitivity is low, particularly in high HIV prevalence settings. Fluorescence microscopy (FM) can improve performance of microscopy and with the new light emitting diode (LED) technologies could be appropriate for peripheral settings. The study aimed t...

متن کامل

[Performance of LED fluorescence microscopy for the detection of acid-fast bacilli from respiratory samples in peripheral laboratories in Argentina].

INTRODUCTION Light-emitting diode fluorescence microscopy (LED-FM) has been endorsed by the World Health Organization (WHO) for tuberculosis diagnosis, but its accuracy in HIV-infected patients remains controversial, and only some few studies have explored procedural factors that may affect its performance. OBJECTIVE To evaluate the performance of LED-FM for tuberculosis diagnosis in patients...

متن کامل

Led Fluorescence Microscopy: Leads the Future of Rapid and Effective Pulmonary Tuberculosis Diagnosis

Early diagnosis and appropriate treatment play an important role in combating the mortality and morbidity caused by Tuberculosis and a rapid, reliable microscopy that can detect acid fast bacilli can be a very useful diagnostic modality. We have evaluated the performance of Light Emitting Diode Fluorescence Microscopy as an alternative to the existing conventional methods in the diagnosis of Pu...

متن کامل

Comparison of Flurochrome , Ziehl-Neelsen and Tan Thiam Hok Staining Methods for Detection of Mycobacterium tuberculosis in Sputums of Patients with Pulmonary Tuberculosis

Abstract Background and objectives: Direct smear microscopy, because of its simplicity, rapidity, low cost and relatively sensitive is a suitable method to detecting pulmonary tuberculosis. This experiment was aimed at determining the best method for detecting Mycobacterium tuberculosis among three kinds of staining methods: Fluorochrome, Ziehl Neelsen and Tan Thiam Hok . Material and Methods: ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2010