A new TASCA focal plane detector setup and DAQ system
نویسندگان
چکیده
A. Gorshkov, J.M. Gates, R. Graeger, A. Türler, A. Yakushev, D. Ackermann, W. Brüchle, Ch.E. Düllmann, H.G. Essel, E. Jäger, J. Khuyagbaatar, I. Kojouharov, J. Krier, N. Kurz, M. Schädel, B. Schausten, E. Schimpf, J. Dvorak, L.-L. Andersson, D. Rudolph, M. Wegrzecki TU Munich, Garching, Germany; GSI, Darmstadt, Germany; LBNL, Berkeley, CA, U.S.A; University of California, Berkeley, CA, U.S.A.; University of Liverpool, UK; University of Lund, Sweden; ITE, Warsaw, Poland
منابع مشابه
Recoil detector system for the R3B setup
O.A. Kiselev, T. Aumann, W. Catford, M. Chartier, P. Egelhof, H. Emling, M. Freer, J.V. Kratz, M. Labiche,R. Lemmon, T. Nilsson, G. Nyman, G. Schrieder, H. Simon, A. Shrivastava, M Stanoiu, K. Sümmerer for the R3B Collaboration A new universal setup with high effi ciency, acceptance, and resolution for kinematically complete measurements of reactions with high-energy radioactive beams is planne...
متن کاملFirst TASCA Commissioning Experiments in the Small Image Size Mode
Ion-optical calculations with the code TRANSPORT (TRANS) (test reaction 235 MeV Ca + UF4 (0.5 mg/cm) ==> 112) were used as a first step to optimize and to built TASCA [1,2]. As a next step the TASCA Monte-Carlo SIMulation program (TSIM) was developed and was applied [3] showing good agreement with previous results. Results for TASCA in the Small Image Size Mode (SIM) are compared in Table 1. Sm...
متن کاملThe HADES Upgrade: first Results
During the year 2010 the HADES Upgrade project has been finalized and the spectrometer has been commissioned in three test beam times at the end of the year. The HADES upgrade program had the following main goals: (1) The installation of a new Resistive Plate Chamber (RPC) detector to increase the time resolution and granularity of the time-of-flight system at the lower polar angles (θ < 45). (...
متن کاملDABC data acquisition input for slow control variables
The Data Acquisition Backbone Core (DABC) is a software framework to run DAQ with distributed event building on high performance Linux clusters [1]. There are several use cases, especially in test beam times where the setup during data taking is intentionally changed very often, and the interpretation of the acquired detector data depends on the experimental set-up. Usually, the set-up is manag...
متن کاملThe front-end electronics for the 1.8-kchannel SiPM tracking plane in the NEW detector
NEW is the first phase of NEXT-100 experiment, an experiment aimed at searching for neutrinoless double-beta decay. NEXT technology combines an excellent energy resolution with tracking capabilities thanks to a combination of optical sensors, PMTs for the energy measurement and SiPMs for topology reconstruction. Those two tools result in one of the highest background rejection potentials in the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2010