A Novel Method to Detect an Oxygenator Defect Prior to Cardiopulmonary Bypass Initiation.

نویسندگان

  • Armindo Fernandes
  • Eric Laliberte
  • Karine Toledano
  • Philippe Demers
چکیده

Cardiopulmonary bypass (CPB) is a common practice in our era. The medical technology used for cardiac surgery goes through rigorous testing to ensure its safety. Unfortunately, it is not fail proof. Oxygenator failures are a rare occurrence but may lead to catastrophic events. We present a case where the preparation for initiating CPB was complicated by an oxygenator defect. After thorough examination, the oxygenator was found leaking from the gas exhaust port suggesting a disruption in continuity of the fibers. This was found by the vigilance of the perfusionist and a creative method to quickly assess the integrity of the oxygenation device. We describe a simple technique to help diagnose an oxygenator leak.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Randomized trial of the Terumo Capiox FX05 oxygenator with integral arterial filter versus Terumo Capiox Baby RX05 and Terumo Capiox AF02 arterial filter in infants undergoing cardiopulmonary bypass.

UNLABELLED The purpose of this clinical trial was to evaluate the effect of the Terumo Capiox FX05 oxygenator with integrated arterial filter during cardiopulmonary bypass (CPB) compared with the Terumo Capiox RX05 Baby RX and arterial filter on inflammatory mediators and blood product utilization. Forty patients weighing less than 10 kg who underwent congenital heart surgery utilizing cardiopu...

متن کامل

Disconnection of Cobe SMARxT tubing from the venous outlet of the Terumo Capiox SX25RX oxygenator during cardiopulmonary bypass.

The use of surface modified, biocompatible tubing in cardiopulmonary bypass has been reported to decrease the inflammatory responses caused by blood contact with the non endothelial surface of poly vinyl chloride (PVC) tubing. The combination of advances in biocompatible tubing and increased affordability resulted in a change to our cardiopulmonary bypass circuit, with the Terumo Capiox SX25 ox...

متن کامل

Changes in sevoflurane plasma concentration with delivery through the oxygenator during on-pump cardiac surgery.

BACKGROUND It is unclear what factors affect the uptake of sevoflurane administered through the membrane oxygenator during cardiopulmonary bypass (CPB) and whether this can be monitored via the oxygenator exhaust gas. METHODS Stable delivery of sevoflurane was administered to 30 elective cardiac surgery patients at 1.8 vol% (inspiratory) via the anaesthetic circuit and ventilator. During CPB,...

متن کامل

A fax-back oxygenator-perfusionist clinical performance data collection and statistical analysis method.

A method to collect clinical oxygenator performance data daily is described. At the end of a bypass procedure, the perfusionist fills in a fax-back form designed to automatically input patient-oxygenator performance data into a computer spreadsheet. Multiple blood gases, FiO2, gas and blood flow data, venous oxygenator blood inlet conditions (hemoglobin, O2 saturation, hematocrit and temperatur...

متن کامل

Extraction of Nitroglycerin by a Membrane Oxygenator

This study examined the extraction efficiency of a membrane oxygenator for nitroglycerin (NTG). An In-Vitro cardiopulmonary bypass circuit was constructed to mimic clinical conditions. A NTG solution (150 ng/ml) was placed into the circuit via a glass cardiotomy reservoir and circulated at 5 Ll min for 60 min. Analysis of NTG samples obtained during the study showed that the oxygenator initiall...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 47 3  شماره 

صفحات  -

تاریخ انتشار 2015