Effect of Breath Holding on Blood Flow Measurement using Fast Velocity Encoded Cine MR Imaging
نویسندگان
چکیده
Introduction Velocity encoded tine (VEC) MR imaging provides quantitative assessment of blood flow in the cardiovascular system. With use of segmented k-space fast VEC MR imaging, noninvasive assessment of blood flow and vasodilator flow reserve in the coronary artery and coronary arterial bypass graft can be obtained within a single breath-hold time. However, it has been pointed out that blood flow measurement with breath-hold MR imaging may be altered in comparison to the physiological blood flow during regular breathing, since breath holding can change intrathoracic pressure which affects venous return to the heart. Paulev P et al [l] reported that cardiac output was 20-40 percent lower than the control values if subjects held their breath with relatively high intrapulmonic pressure using Valsalva maneuver. The purpose of the current study was to determine if breath-hold MR measurement of blood flow in the aorta and pulmonary artery can be significantly altered in comparison to that measured during regular breathing.
منابع مشابه
Valvular Disease
Methods: Magnetic Resonance Imaging of cardiac valves requires state of the art equipement such as a 1.5 or 3 Tesla magnet and a surface coil. Three principal sequences are required [1]: 1) Black blood, 2) cine steady state free precession (CineSSFP), and 3) phase contrast velocity encoded cine (VENCine). Black blood images are obtained by preparation of a fast spin echo sequences with a nonsel...
متن کاملInfluence of Spatial Resolution in Three-dimensional Cine Phase Contrast Magnetic Resonance Imaging on the Accuracy of Hemodynamic Analysis
INTRODUCTION We aim to elucidate the effect of spatial resolution of three-dimensional cine phase contrast magnetic resonance (3D cine PC MR) imaging on the accuracy of the blood flow analysis, and examine the optimal setting for spatial resolution using flow phantoms. MATERIALS AND METHODS The flow phantom has five types of acrylic pipes that represent human blood vessels (inner diameters: 1...
متن کاملAortic valve planimetry by high-resolution 3-dimensional MR image acquisition with a breath-hold: comparison with conventional cine MR imaging and echocardiography to assess the severity of aortic valve stenosis
Methods In 88 consecutive patients (66.9 ± 9.59 years, 63% men) with varying degrees of aortic valve stenosis, high-resolution 3D SSFP images (3D planimetry; 2.0 mm slice thickness, 20 contiguous slices; image matrix, 256 ‘ 209) were acquired with single breath-hold during mid systole and mid diastole. SSFP cine MR imaging (2D planimetry) and velocity-encoded cine MRI (slice thickness, 4.5 mm) ...
متن کاملPhysiologic change in flow velocity and direction of dural venous sinuses with respiration: MR venography and flow analysis.
BACKGROUND AND PURPOSE Blood flow of the internal jugular vein and intracranial venous sinuses is affected by respiratory state. The purpose of this study was to clarify the changes in flow velocity and direction and signal intensities of sigmoid sinuses on phase-contrast (PC) MR images obtained with regular breathing and with deep inspiratory breath holding. METHODS One hundred seven subject...
متن کاملGender differences in response to cold pressor test assessed with velocity-encoded cine-MR imaging of the coronary sinus
Methods Twenty-four healthy volunteers (12 men, 12 women) underwent MRI in a 3 Tesla scanner (Verio, Siemens, Erlangen, Germany). CPT was performed by immersing the right ankle in ice-water during 4 min. Heart rate and blood pressure were monitored throught the protocol. Coronary sinus flow was measured at rest and during CPT using a non breath-hold velocity encoded phase contrast cine MRI (TR/...