Embolic events during total hip arthroplasty: an echocardiographic study.

نویسندگان

  • Keisuke Hagio
  • Nobuhiko Sugano
  • Masaki Takashina
  • Takashi Nishii
  • Hideki Yoshikawa
  • Takahiro Ochi
چکیده

We performed transesophageal echocardiography on 88 patients treated with cementless or hybrid total hip arthroplasty (THA). We observed a significantly higher frequency of severe embolic events among patients without cup holes during insertion of press-fit cups (46.0%) than in patients with holes (15.6%) (P<.005). During stem insertion, severe embolic events occurred in 61.5% of hybrid operations and 5.9% of cementless operations. PaO(2), systolic blood pressure, and arterial oxygen saturation decreased significantly in severe embolic events (P<.05). The results indicate that embolic events may occur during THA whether or not cement is used. Based on these findings, we make several recommendations for technique modifications during insertion of both femoral and acetabular components in THA.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In-Hospital Outcomes after Hemiarthroplasty versus Total Hip Arthroplasty for Isolated Femoral Neck Fractures

  Background:    Previous studies suggest total hip arthroplasty may have some benefits compared to hemi-arthroplasty for displaced intracapsular femoral neck fractures in patients more than 60 years of age. The primary research question of our study was whether in-hospital adverse events, post-operative length of stay (LOS) and mortality in patients 60 year of age or older differed between tot...

متن کامل

Embolic Phenomena During Revision Total Hip Arthroplasty: Diagnosis with Transesophageal Echocardiography

Embolic material was seen in the right atrium during one or more phases of revision total hip arthroplasty (THA)in 17 of 21 ASA Class II or Class III patients (77%) who were monitored with transesophageal echocardiography (TEE). The largest volume of embolic material occurred during preparation and insertion of cemented femoral components. Multiple occurrences of embolization during the procedu...

متن کامل

Intraoperative cerebral arterial embolization during total hip arthroplasty.

BACKGROUND Fat embolism to the pulmonary circulation is known to occur during total hip arthroplasty, especially during insertion of a cemented femoral component. Fat and air bubbles may enter the systemic circulation via a patent foramen ovale or through pulmonary circulation. METHODS To determine whether microemboli to the brain were occurring during total hip arthroplasty, 23 patients unde...

متن کامل

Total Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population

Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...

متن کامل

Effectiveness of the ROBODOC system in preventing intraoperative pulmonary embolism.

Intraoperative pulmonary embolism occurs not only during cemented but also during cementless total hip arthroplasty (THA). We determined whether the ROBODOC femoral milling system can reduce intraoperative pulmonary embolism, by using of transesophageal echocardiography and hemodynamic monitoring. We did a prospective clinical trial with 71 patients (75 hips) who were divided into 2 groups: gro...