An Improved Modeling of TDR Signal Propagation for Measuring Complex Dielectric Permittivity

نویسندگان

  • Chih-Ping Lin
  • Shr-Hong Tang
  • Chun-Hung Lin
  • Chih-Chung Chung
چکیده

Time domain reflectometry (TDR) is a measurement technique based upon transmission line theory. The solutions of transmission line equations are reformulated in terms of independent physical properties, instead of coupled per-unit-length circuit parameters. The complete TDR response is effectively modeled by a non-uniform transmission line using the non-recursive ABCD matrix approach. Approaches to calibrate line parameters and perform TDR measurements based upon such model are introduced with an example on dielectric spectroscopy. TDR modeling in terms of decoupled physical parameters and non-recursive algorithm allows more convenient calibration of line parameters and facilitates interpretation of TDR measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-Domain Reflectometry (TDR) Technique for the Estimation of Soil Permittivity

Time Domain Reflectometry (TDR) has been initially developed as a remote sensing electrical measurement tool and it has been widely used to detect cable faults and discontinuities of signal lines (Somlo & Hollway, 1969). Recently, TDR has been widely applied to soil science, hydrology and agronomy to estimate the electrical properties of soils (Courtney, 1998; Evett & Parkin, 2005; Nozaki & Bos...

متن کامل

A FDR Sensor for Measuring Complex Soil Dielectric Permittivity in the 10–500 MHz Frequency Range

Mechanical details as well as electrical models of FDR (frequency domain reflectometry) sensors for the measurement of the complex dielectric permittivity of porous materials are presented. The sensors are formed from two stainless steel parallel waveguides of various lengths. Using the data from VNA (vector network analyzer) with the connected FDR sensor and selected models of the applied sens...

متن کامل

Considerations for Improving the Accuracy of Permittivity Measurement using Time Domain Reflectometry: Air-Water Calibration, Effects of Cable Length

to measure permittivity. In this discussion we will demonstrate the need for carefully choosing the correct In a paper presented by Heimovaara (1993) a method of calibrating waveform analysis method to obtain the best measureTDR sensors was presented using air and water. Time has moved on but time domain reflectometry (TDR) sensors are still calibrated in ment of permittivity. This is crucial f...

متن کامل

Frequency Domain Analysis for Extending Time Domain Reflectometry Water Content Measurement in Highly Saline Soils

TTA especially with the filtering of higher frequencies in cables longer than 3.2 m resulting in increased signal Water content and electrical conductivity of soils are routinely rise time (Heimovaara, 1993; Noborio, 2001). Timing or determined using time-domain reflectometry (TDR) based on analysis length measurement errors associated with finite pixel of signal travel time and attenuation alo...

متن کامل

A Time-Domain Reflectometry Method with Variable Needle Pulse Width for Measuring the Dielectric Properties of Materials

Time-domain reflectometry (TDR) methods used for measuring the dielectric properties of materials mostly utilize step or needle electrical pulses of constant amplitudes and shapes. Our novel approach enables determining the dielectric relaxation time of a sample using the analysis of the amplitudes of reflected pulses of two widths, in addition to bulk dielectric permittivity and electrical con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015