Tissue coverage of paclitaxel and sirolimus eluting stents in long term follow-up: optical coherence tomography study.
نویسندگان
چکیده
BACKGROUND Implantation of drug eluting stents (DES) has become a standard treatment of patients undergoing percutaneous coronary intervention (PCI). Incomplete strut coverage is a potential risk factor for late stent thrombosis. Optical coherence tomography (OCT) enables in vivo identification of incomplete neointimal coverage. METHODS Study included 62 patients after sirolimus eluting stents (SES) or paclitaxel eluting stents (PES) implantation. OCT examination was performed at least 24 months after the initial procedure (35.4± 9.4 months). In cross-sectional still frames selected from each 1 mm of analyzed stents a total number of visible struts and number of struts with or without complete neointimal coverage was assessed. Measurements of neointimal coverage, presented as a mean thickness of tissue, were performed. Patients were followed up for 3 years and the frequency ofmajor adverse cardiac events was recorded. RESULTS In the analyzed 28 SES and 37 PES 9998 struts were identified. Complete neointimalcoverage was observed in 83.5% and 79.2% of SES and PES struts respectively (p = 0.48).There was no difference in incidence of not covered or malapposed struts between SES and PES groups. Mean thickness of the tissue covering SES struts was 0.165 ± 0.095 mm, and 0.157 ± 0.121 mm for PES. The mean neointimal thickness difference (SES vs. PES) was notstatistically significant. In a 36 months follow-up 1 death was observed - potentially attributed to stent thrombosis. CONCLUSIONS A long term OCT follow-up after DES implantation shows high incidence ofuncovered struts regardless of the stent type. Clinical significance of this finding remains questionable and requires further large scale trials.
منابع مشابه
Optical coherence tomography assessment of in vivo vascular response after implantation of overlapping bare-metal and drug-eluting stents.
OBJECTIVES We designed a randomized trial exploiting optical coherence tomography (OCT) to assess coverage and apposition of overlapping bare-metal stents (BMS) and drug-eluting stents (DES) in human coronary arteries. BACKGROUND Overlapping DES impair healing in animals. Optical coherence tomography allows accurate in vivo assessment of stent strut coverage and apposition. METHODS Seventy-...
متن کاملنتایج بالینی پس از آنژیوپلاستی عروق کرونر، بروز حوادث بزرگ قلبی-عروقی و عوارض انواع استنت
Background: Cardiovascular diseases alone have become the leading cause of death worldwide. One of the treatment methods cardiovascular disease is angioplasty. This study aimed to investigate the clinical results after coronary artery angioplasty, based on the incidence of major cardiovascular events with emphasis on stent types. Methods: In this retrospective cross-sectional study, the preval...
متن کاملStent coverage and neointimal proliferation in bare metal stents postdilated with a Paclitaxel-eluting balloon versus everolimus-eluting stents: prospective randomized study using optical coherence tomography at 6-month follow-up.
BACKGROUND In this randomized trial, strut coverage and neointimal proliferation of a therapy of bare metal stents (BMSs) postdilated with the paclitaxel drug-eluting balloon (DEB) was compared with everolimus drug-eluting stents (DESs) at 6-month follow-up using optical coherence tomography. We hypothesized sufficient stent coverage at follow-up. METHODS AND RESULTS A total of 105 lesions in...
متن کاملThe relationship between post-stent strut apposition and follow-up strut coverage assessed by a contour plot optical coherence tomography analysis.
OBJECTIVES This study sought to evaluate the relationship between post-stent strut apposition and follow-up strut coverage using contour plot optical coherence tomographic analysis. BACKGROUND Tracking the fate of interested regions of struts at different time points has not been investigated. METHODS Post-intervention and 6-month follow-up optical coherence tomographic evaluations were per...
متن کاملComparison of neointimal coverage of sirolimus-eluting stents and paclitaxel-eluting stents using optical coherence tomography at 9 months after implantation.
BACKGROUND The differences between using sirolimus-eluting stents (SESs) and paclitaxel-eluting stents (PESs) in the vascular response at 9 months after implantation were examined with optical coherence tomography (OCT). METHODS AND RESULTS OCT was carried out in 33 SESs [33 patients, 19 with acute coronary syndrome (ACS) and 14 with stable angina pectoris (SAP)] and 27 PESs (27 patients, 15 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Cardiology journal
دوره 20 3 شماره
صفحات -
تاریخ انتشار 2013