A method for model-free partial volume correction in oncological PET

نویسندگان

  • Frank Hofheinz
  • Jens Langner
  • Jan Petr
  • Bettina Beuthien-Baumann
  • Liane Oehme
  • Jörg Steinbach
  • Jörg Kotzerke
  • Jörg van den Hoff
چکیده

UNLABELLED BACKGROUND As is well known, limited spatial resolution leads to partial volume effects (PVE) and consequently to limited signal recovery. Determination of the mean activity concentration of a target structure is thus compromised even at target sizes much larger than the reconstructed spatial resolution. This leads to serious size-dependent underestimates of true signal intensity in hot spot imaging. For quantitative PET in general and in the context of therapy assessment in particular it is, therefore, mandatory to perform an adequate partial volume correction (PVC). The goal of our work was to develop and to validate a model-free PVC algorithm for hot spot imaging. METHODS The algorithm proceeds in two automated steps. Step 1: estimation of the actual object boundary with a threshold based method and determination of the total activity A measured within the enclosed volume V. Step 2: determination of the activity fraction B, which is measured outside the object due to the partial volume effect (spill-out). The PVE corrected mean value is then given by Cmean = (A+B)/V. For validation simulated tumours were used which were derived from real patient data (liver metastases of a colorectal carcinoma and head and neck cancer, respectively). The simulated tumours have characteristics (regarding tumour shape, contrast, noise, etc.) which are very similar to those of the underlying patient data, but the boundaries and tracer accumulation are exactly known. The PVE corrected mean values of 37 simulated tumours were determined and compared with the true mean values. RESULTS For the investigated simulated data the proposed approach yields PVE corrected mean values which agree very well with the true values (mean deviation (± s.d.): (-0.8±2.5)%). CONCLUSIONS The described method enables accurate quantitative partial volume correction in oncological hot spot imaging.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Partial Volume Effect Correction Tailored for 18F-FDG-PET Oncological Studies

We have developed, optimized, and validated a method for partial volume effect (PVE) correction of oncological lesions in positron emission tomography (PET) clinical studies, based on recovery coefficients (RC) and on PET measurements of lesion-to-background ratio (L/B m) and of lesion metabolic volume. An operator-independent technique, based on an optimised threshold of the maximum lesion upt...

متن کامل

Effect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis

Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...

متن کامل

An MR image-guided, voxel-based partial volume correction method for PET images.

PURPOSE Partial volume effect in positron emission tomography (PET) can cause incorrect quantification of radiopharmaceutical uptake in functional imaging. A PET partial volume correction method is presented to attenuate partial volume blurring and to yield voxel-based corrected PET images. METHODS By modeling partial volume effect as a convolution of point spread function of the PET scanner,...

متن کامل

Partial volume correction for positron emission images using the wavelet transform

A method for partial volume correction of positron emission tomography (PET) images is proposed. The method is based on combining information from PET and high resolution anatomical images. Two different algorithms fast wavelet transform and à trous were implemented in order to decompose the PET and high resolution images. Results obtained using several simulated images show a significant parti...

متن کامل

Relationship between F-FDG PET SUV with Partial Volume Correction and Histology in Gastric and Gastro-Oesophageal Cancer

In vivo molecular imaging techniques is increasingly used in the management of oncological patients, allowing different aspects of oncological pathologies to be assessed (e.g. metabolism, hypoxia) non invasively. The possibility to extract indexes of disease from in vivo biomedical images and to associate them with their biological drivers opens new prospective on the role of in vivo molecular ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2012