Follow-up of true visceral artery aneurysm after coil embolization by three-dimensional contrast-enhanced MR angiography.

نویسندگان

  • Masamichi Koganemaru
  • Toshi Abe
  • Masaaki Nonoshita
  • Ryoji Iwamoto
  • Masashi Kusumoto
  • Asako Kuhara
  • Tomoko Kugiyama
چکیده

PURPOSE We aimed to evaluate the outcomes of coil embolization of true visceral artery aneurysms by three-dimensional contrast-enhanced magnetic resonance (MR) angiography. MATERIALS AND METHODS We used three-dimensional contrast-enhanced MR angiography, which included source images, to evaluate 23 patients (mean age, 60 years; range, 28-83 years) with true visceral artery aneurysms (splenic, n=15; hepatic, n=2; gastroduodenal, n=2; celiac, n=2; pancreaticoduodenal, n=1; gastroepiploic, n=1) who underwent coil embolization. Angiographic aneurysmal occlusion was revealed in all cases. Follow-up MR angiography was conducted with either a 1.5 or 3 Tesla system 3-25 months (mean, 18 months) after embolization. MR angiography was evaluated for aneurysmal occlusion, hemodynamic status, and complications. RESULTS Complete aneurysmal occlusion was determined in 22 patients (96%) on follow-up MR angiography (mean follow-up period, 18 months). Neck recanalization, which was observed at nine and 20 months after embolization, was confirmed in one of eight patients (13%) using a neck preservation technique. In this patient, a small neck recanalization covered by a coil mass was demonstrated. The complete hemodynamic status after embolization was determined in 21 patients (91%); the visualization of several collateral vessels, such as short gastric arteries, after parent artery occlusion was poor compared with that seen on digital subtraction angiography in the remaining two patients (9%). An asymptomatic localized splenic infarction was confirmed in one patient (4%). CONCLUSION Our study presents the follow-up results from three-dimensional contrast-enhanced MR angiography, which confirmed neck recanalization, the approximate hemodynamic status, and complications. This effective and less invasive method may be suitable for serial follow-up after coil embolization of true visceral aneurysms.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-resolved Magnetic Resonance Angiography for assessment of recanalization after coil embolization of visceral artery aneurysms

BACKGROUND Follow-up imaging after coil embolization of visceral artery aneurysms is important for detecting recanalization. However, CT examination is susceptible to coil artifacts, which sometimes makes it difficult to assess recanalization. We report 2 cases where recanalization was successfully visualized using time-resolved magnetic resonance angiography after coil embolization of visceral...

متن کامل

Single-stage Coil Embolization for Kissing Aneurysms of the Internal Carotid Artery Using Enterprise Stent: Three Cases Reports

Purpose: Kissing aneurysms (KAs) are caused by the rare incidence of two aneurysms with different cervixes mutually contacting each other, with craniotomy surgical clipping having been reported as difficult. The objective was to investigate the treatment outcome of single-stage coil embolization using an Enterprise stent for internal carotid artery KA. Materials and Methods: The subjects consis...

متن کامل

Treatment of intracranial broad-neck aneurysms with a new self-expanding stent and coil embolization.

BACKGROUND AND PURPOSE Endovascular treatment of broad-neck intracranial aneurysms with detachable coils requires special techniques. Placement of a stent over the aneurysm neck and secondary coil embolization prevents coil migration and allows attenuated packing of the coils. However, access for the stent-delivery system can be technically limited in tortuous anatomy. We present six cases of b...

متن کامل

Time-Resolved 3D Contrast-Enhanced MRA on 3.0T: a Non-Invasive Follow-Up Technique after Stent-Assisted Coil Embolization of the Intracranial Aneurysm

OBJECTIVE To evaluate the usefulness of time-resolved contrast enhanced magnetic resonance angiography (4D MRA) after stent-assisted coil embolization by comparing it with time of flight (TOF)-MRA. MATERIALS AND METHODS TOF-MRA and 4D MRA were obtained by 3T MRI in 26 patients treated with stent-assisted coil embolization (Enterprise:Neuroform = 7:19). The qualities of the MRA were rated on a...

متن کامل

Repeated Subarachnoid Hemorrhage Due to a Ruptured Radiation-Induced Aneurysm in a Patient with Suprasellar Germinoma Treated By Radiation Therapy 27 Years Previously: A Case Report

Background: Radiation-induced intracranial aneurysm (RIICA) is a rare complication. From the literature, 74.1% of the reported RIICA ruptured with aneurysmal subarachnoid hemorrhage (SAH), and the mortality rate was 42.3%. Here, we report a case of repeated SAH due to a RIICA after surgical clipping. Case description: A 42-year-old woman presented with SAH. She had undergone radiotherapy for su...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Diagnostic and interventional radiology

دوره 20 2  شماره 

صفحات  -

تاریخ انتشار 2014