Fusion of detected multi-channel maternal electrocardiogram (ECG) R-wave peak locations
نویسندگان
چکیده
BACKGROUND Almost all promising non-invasive foetal ECG extraction methods involve accurately determining maternal ECG R-wave peaks. However, it is not easy to robustly detect accurate R-wave peaks of the maternal ECG component in an acquired abdominal ECG since it often has a low signal-to-noise ratio (SNR), sometimes containing a large foetal ECG component or other noises and interferences. This paper discusses, under the condition of acquiring multi-channel abdominal ECG signals, how to improve the robustness of maternal ECG R-wave peak detection. METHODS On the basis of summarising the current single channel ECG R-wave peak detection methods, the paper proposed a specific fusion algorithm of detected multi-channel maternal ECG R-wave peak locations. The proposed entire algorithm was then tested using two databases; one database, created by us, was composed of 343 groups of 8-channel data collected from 78 pregnant women, and the other one, called the challenge database, was from the Physionet/Computing in Cardiology Challenge 2013, including 175 groups of 4-channel data. When using these databases, each group of data was classified into two parts, called the training part and the validation test part respectively; the training part was the first 8.192 s of each group of data and the validation test part was the next 8.192 s. RESULTS To show the results, three evaluation parameters-sensitivity (Se), positive predictive value (PPV) and F1-are used. The validation test results for the database we collected are Se = 99.93 %, PPV = 99.98 %, and F1 = 99.95 %, while the results for the challenge database are Se = 99.91 %, PPV = 99.86 %, and F1 = 99.88 %. CONCLUSION The results of the test show that the robustness of our proposed whole fusion algorithm was superior to that of other outstanding algorithms for maternal R-wave detection, and is much better than that of single channel maternal R-wave detection algorithms.
منابع مشابه
Fusion Framework for Emotional Electrocardiogram and Galvanic Skin Response Recognition: Applying Wavelet Transform
Introduction To extract and combine information from different modalities, fusion techniques are commonly applied to promote system performance. In this study, we aimed to examine the effectiveness of fusion techniques in emotion recognition. Materials and Methods Electrocardiogram (ECG) and galvanic skin responses (GSR) of 11 healthy female students (mean age: 22.73±1.68 years) were collected ...
متن کاملEfficient Fetal-Maternal ECG Signal Separation from Two Channel Maternal Abdominal ECG via Diffusion-Based Channel Selection
There is a need for affordable, widely deployable maternal-fetal ECG monitors to improve maternal and fetal health during pregnancy and delivery. Based on the diffusion-based channel selection, here we present the mathematical formalism and clinical validation of an algorithm capable of accurate separation of maternal and fetal ECG from a two channel signal acquired over maternal abdomen. The p...
متن کاملDetermination the Normal Parameters (amplitude and duration) of Electrocardiogram Waves in River Buffaloes (Bubalus Bubalis) of Khuzestan
An easy way to evaluate the cardiovascular system is recording the cardiac electrical activities. Reviewing the available literatures suggests that buffalos ECG compared to other large animals have been neglected and the carried out studies in this field are too limited. Using this method for the diagnosis of cardiac disorders needs the standardization, not only among animal species but also am...
متن کاملINTELLIGENT TECHNIQUE OF CANCELING MATERNAL ECG IN FECG EXTRACTION
In this paper, we propose a technique of artificial intelligence called adaptive neuro fuzzy inference system (ANFIS) for canceling maternal electrocardiogram (MECG) in fetal electrocardiogram extraction (FECG).This technique is used to estimate the MECG present in the abdominal signal of a pregnant woman. The FECG is then extracted by subtracting the estimated MECG from the abdominal signal. P...
متن کاملNeuro-ANFIS Architecture for ECG Rhythm-Type Recognition Using Different QRS Geometrical-based Features
The paper addresses a new QRS complex geometrical feature extraction technique as well as its application for electrocardiogram (ECG) supervised hybrid (fusion) beat-type classification. To this end, after detection and delineation of the major events of ECG signal via a robust algorithm, each QRS region and also its corresponding discrete wavelet transform (DWT) are supposed as virtual images ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -
تاریخ انتشار 2016