Respiratory Magnetogram Detected with a MEMS Device

نویسندگان

  • Saul M. Dominguez-Nicolas
  • Raul Juarez-Aguirre
  • Agustin L. Herrera-May
  • Pedro Garcia-Ramirez
  • Eduard Figueras
  • Edmundo A. Gutierrez-D.
  • Jesus A. Tapia
  • Argelia Trejo
  • Elias Manjarrez
چکیده

Magnetic fields generated by the brain or the heart are very useful in clinical diagnostics. Therefore, magnetic signals produced by other organs are also of considerable interest. Here we show first evidence that thoracic muscles can produce a strong magnetic flux density during respiratory activity, that we name respiratory magnetogram. We used a small magnetometer based on microelectromechanical systems (MEMS), which was positioned inside the open thoracic cage of anaesthetized and ventilated rats. With this new MEMS sensor of about 20 nT resolution, we recorded a strong and rhythmic respiratory magnetogram of about 600 nT.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Digital Signal Processing by Virtual Instrumentation of a MEMS Magnetic Field Sensor for Biomedical Applications

We present a signal processing system with virtual instrumentation of a MEMS sensor to detect magnetic flux density for biomedical applications. This system consists of a magnetic field sensor, electronic components implemented on a printed circuit board (PCB), a data acquisition (DAQ) card, and a virtual instrument. It allows the development of a semi-portable prototype with the capacity to fi...

متن کامل

Automated McIntosh-Based Classification of Sunspot Groups Using MDI Images

A hybrid system for the automated detection and McIntosh-based classification of sunspot groups on SOHO/MDI white-light images using active-region data extracted from SOHO/MDI magnetogram images is presented in this paper. After sunspots are detected from MDI white-light images they are grouped/clustered using MDI magnetogram images. By integrating image-processing and Neural Networks technique...

متن کامل

Comprehensive Electromechanical Analysis of MEMS Variable Gap Capacitors

This paper presents a comprehensive case study on electro-mechanical analysis of MEMS[1] variable capacitors. Using the fundamental mechanical and electrical equations, static and dynamic behaviors of the device are studied. The analysis is done for three different modes, namely: dc (static mode), small signal ac and large signal regime. A complete set of equations defining dynamic behavior of ...

متن کامل

ar X iv : a st ro - p h / 99 07 25 6 v 1 1 9 Ju l 1 99 9 Characteristics of MHD Oscillations Observed with MDI

We report on the spatial distribution of magnetogram oscillatory power and phase angles between velocity and magnetogram signals as observed with the Michelson Doppler Imager. The dataset is 151.25 ′′ × 151.25 ′′ containing sunspot from Dec 2, 1997 with a temporal sampling interval of 60 seconds and spatial sampling of 0.605 ′′. Simultaneously observed continuum intensity and surface velocity a...

متن کامل

A New Scheme for Determination of Respiration Rate in Human Being using MEMS Based Capacitive Pressure Sensor: Simulation Study

In this paper, a MEMS based capacitive nasal sensor system for measuring Respiration Rate (RR) of human being is developed. At first two identical diaphragm based MEMS capacitive nasal sensors are designed and virtually fabricated. A proposed schematic of the system consists of signal conditioning circuitry alongwith the sensors is described here. In order to measure the respiration rate the se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -