Hemodynamic response to carbon monoxide.
نویسنده
چکیده
Historically, and at present, carbon monoxide is a major gaseous poison responsible for widespread morbidity and mortality. From threshold to maximal nonlethal levels, a variety of cardiovascular changes occur, both immediately and in the long term, whose homeostatic function it is to renormalize tissue oxygen delivery. However, notwithstanding numerous studies over the past century, the literature remains equivocal regarding the hemodynamic responses in animals and humans, although CO hypoxia is clearly different in several respects from hypoxic hypoxia. Factors complicating interpretation of experimental findings include species, CO dose level and rate, route of CO delivery, duration, level of exertion, state of consciousness, and anesthetic agent used. For example, tachycardia is commonly observed, although bradycardia also can result from myocardial and/or central nervous system (CNS) hypoxemia at high carboxyhemoglobin (COHb) saturations, as can electrocardiographic abnormalities. Augmented cardiac output usually observed with moderate COHb may be compromised in more severe poisoning for the same reasons, such that regional or global ischemia result. The hypotension usually seen in most animal studies is thought to be a primary cause of CNS damage resulting from acute CO poisoning, yet the exact mechanism(s) remains unproven in both animals and humans, as does the way in which CO produces hypotension. This review briefly summarizes the literature relevant to the short- and long-term hemodynamic responses reported in animals and humans. It concludes by presenting an overview using data from a single species in which the most complete work has been done to date.
منابع مشابه
SMART ROOM CARBON MONOXIDE MONITORING AND CONTROL SYSTEM
Carbon Monoxide (CO) is the most abundant air pollutant gas and accumulates rapidly to dangerous concentrations even in areas that seem to be well ventilated. Carbon monoxide detectors/alarm systems exist but people who are old, hearing impaired, partially sighted or heavy sleepers may not get the warning or find it difficult to wake up and get out in the event of dangerous concentration of CO ...
متن کاملProtective Effects of α-Tocopherol on ABR Threshold Shift in Rabbits Exposed to Noise and Carbon Monoxide
Noise induced hearing loss (NIHL) is one of the most important occupational disease worldwide. NIHL has been found potentiate by simultaneous carbon monoxide (CO) exposure. Free radicals have been implicated in cochlear damage resulted from the exposure to noise and due to the CO hypoxia. This study examined whether α-tocopherol administration, as a free radical scavenger, causes the attenuatio...
متن کاملCarbon monoxide inhalation reduces pulmonary inflammatory response during cardiopulmonary bypass in pigs.
BACKGROUND Cardiopulmonary bypass (CPB) is associated with pulmonary inflammation and dysfunction. This may lead to acute lung injury and acute respiratory distress syndrome with increased morbidity and mortality. The authors hypothesized that inhaled carbon monoxide before initiation of CPB would reduce inflammatory response in the lungs. METHODS In a porcine model, a beating-heart CPB was u...
متن کاملHemodynamic profiles of intubated and mechanically ventilated carbon monoxide-poisoned patients during systemic hyperbaric oxygen therapy
BACKGROUND Carbon monoxide (CO) poisoning can be a life threatening condition. Systemic hyperbaric oxygen (HBO) therapy is used to induce CO detoxification. However, little is known about the hemodynamic response to HBO in severely intoxicated patients. METHODS We retrospectively analyzed the medical records of 6 CO-poisoned patients treated with propofol, rocuronium bromide, and HBO. The HBO...
متن کاملAdsorption of Carbon Monoxide on a (6, 6) Armchair Carbon Nanotube: Ab initio Study
Perhaps the more interesting nanostructures with large application potential, from transistors to probes, are carbon nanotubes. One of the most widely uses of these nanostructures are their applications as gas detector, which is an important application in the field se of environmental technologies. The present work studies the adsorption of carbon monoxide on a (6, 6) armchair carbon nanotube ...
متن کاملAnalysis of temporal - spatial distribution Carbon monoxide gas in the atmosphere of Iran using Aqua/AIRS data
Considering the vital importance of air and the increasing trace of its contaminating factors, it is necessary to study the contaminating factors in order to be aware of the existing situation. The phenomenon of air pollution is one of the most important problems in many parts of Iran, due to several reasons, increasing the amount of it day by day. Carbon monoxide is one of the most dangerous p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Environmental Health Perspectives
دوره 77 شماره
صفحات -
تاریخ انتشار 1988