Simple Cost-effective Scour Sensor

نویسنده

  • Farhad Ansari
چکیده

Local bridge scour is caused by the interference of bridge piers with the flow of water and is characterized by the formation of scour holes. Local scour occurs at a bridge pier when the local flow field is strong enough to remove bed materials. Several variables affect the scour depth including the flow intensity, the relative flow depth, the pier-width, and the properties of the river bed materials. This study developed a fiber optic scour sensor capable of monitoring and providing quantitative characteristics of both scour depth and flow processes, i.e. rate. The proposed fiber optic scour sensor will include a single Fiber Optic Bragg Grating (FBG) sensor embedded inside a rod cantilevered into the river bed. The sensor will allow for better monitoring of scour and therefore better bridge maintenance. Research results proved that the simple concept for the development of a very low cost sensor with only one sensing element is sound. The simplicity of the sensor allows for widespread implementation in myriads of scour critical bridges. Field experimentations have been limited to few tests; however, and the system has not been thoroughly tested under flood situations. Further experiments are necessary to accurately determine the sensor resolution and repeatability under field conditions and to further establish the software for more sophisticated and user-friendly remote monitoring applications. The contents of this report reflect the view of the author, who is responsible for the facts and the accuracy of the data presented herein. The contents do not necessarily reflect the official views or policies of the Illinois Center for Transportation, the Illinois Department of Transportation, or the Federal Highway Administration. This report does not constitute a standard, specification, or regulation. Trademark or manufacturers' names appear in this report only because they are considered essential to the object of this document and do not constitute an endorsement of product by the Federal Highway Administration, the Illinois Department of Transportation, or the Illinois Center for Transportation. ii EXECUTIVE SUMMARY Local bridge scour is caused by the interference of bridge piers with the flow of water and is characterized by the formation of scour holes. Local scour occurs at a bridge pier when the local flow field is strong enough to remove bed materials. Several variables affect the scour depth including the flow intensity, the relative flow depth, the pier-width, and the properties of the river bed materials. This study developed a fiber …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-time Bridge Scour Monitoring System by Using Capacitor Sensor

Scour is the erosion of stream bed or bank material from bridge foundations due to flowing of water. Data logging from sensor and electronic communication systems can monitor scour in real-time to ensure the integrity of bridge structure. A number of parameters are associated with scour, thus different types of sensor are required to measure the individual affecting factor. A simple capacitive ...

متن کامل

RSS Based Bridge Scour Measurement Using Underwater Acoustic Sensor Networks

Bridge Scour is one of the major causes of bridge failures all around the world and there have been significant efforts for its detection and measurement using different acoustic approaches. In this paper, we propose and investigate an effective method to utilize Received Signal Strength (RSS) for measuring scour depth where acoustic sensors are deployed. We also extend a statistical testing to...

متن کامل

Bridge Local Scour Monitoring System Using MEMS Sensor Zigbee Network

Wireless MEMS sensors network has been widely used in many fields. In this paper the MEMS pressure sensor is integrated on a sensor board with Zigbee sensor network for real-time local bridge scour depth monitoring during a flood. The wireless MEMS pressure sensor scour monitoring system has been developed and tested in the laboratory. Local scour is one of the major factors for bridge failure....

متن کامل

White Paper: Tiltmeter-Based Bridge Scour Monitoring

Scour is by far the primary cause of bridge failures in the United States. Scour and other hydraulic effects are particularly threatening because the deterioration is often invisible , hidden beneath turbid water. Many scour monitoring methods attempt to measure the development of scour pockets themselves. However, this is difficult due to debris — both floating and submerged — and shifting str...

متن کامل