Organic dust and gaseous contaminants at wood working shops.
نویسندگان
چکیده
Airborne dust bioaerosols, ammonia and formaldehyde levels were determined inside two different (ventilated and unventilated) wood working shops. Airborne dust was found at mean values of 4.3 and 3.01 mg m(-3). These levels were higher than that recommended by Egyptian environmental law [1 mg m(-3) indoor maximum allowable concentration (MAC) for hard wood]. The highest frequency of aerodynamic size distribution of airborne wood dust was detected at a diametre of 4.9 microm which was recorded during a machining operation. Total viable bacteria were recorded at a mean value of 10(4) colony-forming units (cfu) m(-3), whereas Gram-negative bacteria were found at very low counts (10(1) cfu m(-3)). Fungi levels were recorded at mean values of 10(3) and 10(2) cfu m(-3) in ventilated and unventilated shops, respectively. Penicillium, Aspergillus, Cladosporium and yeast species were dominant isolates. Moreover, actinomycetes were found at a mean value of 10(3) cfu m(-3) at both workshops. Ammonia was detected in relatively low concentrations (mean values of 457 and 623 microg m(-3)), whereas formaldehyde was found in relatively moderate concentrations (mean values of 0.42 and 0.64 ppm).
منابع مشابه
Wood dust exposure in wood industry and forestry.
The aim of the study was to determine occupational exposure in Croatian wood processing industry and forest workers to harmful effects of wood dust on the risk of nose, nasal cavity and lung carcinoma. Mass concentrations of respirable particles and total wood dust were measured at two wood processing plants, three woodwork shops, and one lumbering site, where 225 total wood dust samples and 22...
متن کاملHeat Recirculation Effect on the Structure of Wood Dust Flame Propagation
A model for heat-recirculating micro combustor is developed. It investigates the structure of laminar, one-dimensional and steady state flame propagation in uniformly premixed wood particles with considering the effects of heat recirculation caused by configuration of micro combustor. The flame structure is divided into three regions: a preheat-devolatilization zone where the rate of the gas-ph...
متن کاملPersonal exposure to wood dust among workers in NekaChoob factory in 2013
Background and Purpose: Inhalation of hardwood dust may produce a range of adverse health effects in the upper and lower respiratory system, including asthma, along with Sino-nasal cancer and nasopharyngeal cancer. This study was carried out to evaluate personal exposure to wood dust among workers in chipboard and furniture production saloons in Neka Choob factory, Iran. Materials a...
متن کاملEffect of the temperature difference between gas and organic dust on propagating spherical flames
A new analytical study performed to investigate the effect of the temperature difference between gas and particle in propagation of the spherical flames. The combustible system is containing uniformly distributed volatile fuel particles in an oxidizing gas (Air) mixture. The model includes evaporation of volatile matter of dust particles to known gaseous fuel (methane) and the single-stage reac...
متن کاملThe effect of simulated dust storm on wood development and leaf stomata in Quercus brantii L
Dust storms are increasingly threatening the forest ecosystem in Western Iran. Due to its coverage of vast area of Zagros forest, the Quercus brantii is at the front line of the attack. Most tree deaths in this forest are from this species. This study aims to investigate the effect of simulated dust on wood development and leaf stomata from seedlings of Persian oak. The oak seedlings were...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of environmental monitoring : JEM
دوره 2 1 شماره
صفحات -
تاریخ انتشار 2000