Variability components of standard automated perimetry and frequency-doubling technology perimetry.
نویسندگان
چکیده
PURPOSE To evaluate and compare intra- and intertest variability components for both standard automated perimetry (SAP) and frequency-doubling technology (FDT) perimetry in a small group of normal individuals and patients with glaucoma. METHODS The method of constant stimuli (MOCS) was used to examine matched test locations with both SAP and FDT perimetry stimuli in a group of eight normal individuals and seven patients with glaucoma. Subjects were tested weekly at three predetermined visual field loci for 5 consecutive weeks. Frequency-of-seeing (FOS) curves were generated and used to quantify threshold sensitivity (50% seen on FOS, in decibels), intratest variability (FOS interquartile range, in decibels), and intertest variability (interquartile range of weekly repeated threshold determinations, in decibels). RESULTS In patients with glaucoma, SAP intra- and intertest variabilities were found to increase with sensitivity reductions, as previously reported. FDT perimetry revealed that both intra- and intertest variability components did not appreciably change with reductions in sensitivity. With the measurement scales used in this investigation, both intra- and intertest variability components were significantly greater for SAP than for FDT perimetry (P < 0.001 and P = 0.003, respectively). Intratest variability exceeded intertest variability for both SAP (P = 0.001) and FDT perimetry (P < 0.001). CONCLUSIONS For both SAP and FDT perimetry, variability occurring within a single test session contributed more to total variability than between-session variability. When the measurement scales available on commercial instrumentation were used, FDT perimetry exhibited significantly less variability than SAP, especially within regions of visual field sensitivity loss. FDT perimetry therefore shows promise as an effective test for detecting progressive glaucomatous visual field loss, although prospective longitudinal validation is still required to determine sensitivity to change.
منابع مشابه
Visual function-specific perimetry for indirect comparison of different ganglion cell populations in glaucoma.
PURPOSE To compare short-wavelength automated perimetry, frequency-doubling technology perimetry, and motion-automated perimetry, each of which assesses different aspects of visual function, in eyes with glaucomatous optic neuropathy and ocular hypertension. METHODS One hundred thirty-six eyes from 136 subjects were evaluated with all three tests as well as with standard automated perimetry. ...
متن کاملClinical comparison of frequency doubling technology perimetry and Humphrey perimetry.
AIM To determine the number of missed points on frequency doubling technology (FDT) perimetry that optimise the sensitivity and specificity of the test and to determine the topographical accuracy of the test in a clinical setting. METHODS In a prospective study, the perimetric data from 99 patients who underwent both FDT perimetry in the screening mode and Humphrey 24-2 (H24-2) were used to d...
متن کاملComparison of standard automated perimetry, frequency-doubling technology perimetry, and short-wavelength automated perimetry for detection of glaucoma.
PURPOSE To compare the performance of standard automated perimetry (SAP), frequency-doubling technology (FDT) perimetry, and short-wavelength automated perimetry (SWAP) in detecting glaucoma. METHODS One hundred thirty-two eyes of 95 glaucoma patients and 37 normal subjects had retinal nerve fiber layer (RNFL) imaging and visual field testing by SAP, Matrix FDT perimetry, and Swedish interact...
متن کاملComparison of visual evoked potentials, automated perimetry and frequency-doubling perimetry in early detection of glaucomatous visual field loss.
The present study compares frequency-doubling perimetry (FDP), automated perimetry (AP) and visual evoked potentials (VEP) for their ability to diagnose early glaucoma. In present study 224 patients of Clinic for Eye Diseases, Clinical Hospital "Sestre Milosrdnice" that had diagnosis of open angle glaucoma and glaucomatous visual field loss proven by automated static perimetry on only one eye w...
متن کاملA Comparison of the Effects of Neutral Density Filters and Diffusing Filters on Motion Detection Perimetry, White-on-white Perimetry and Frequency Doubling Perimetry
Background: Motion detection perimetry and frequency doubling perimetry are methods that have been developed with the goal of detecting glaucomatous field defects earlier than conventional white-on-white perimetry. It is well recognized that the development of cataract and pupillary constriction can significantly influence perimetric thresholds when screening for, or following the progression o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 42 6 شماره
صفحات -
تاریخ انتشار 2001