Influence of hemoglobin S adducts on hemoglobin A2 quantification by HPLC.

نویسندگان

  • D D Suh
  • J S Krauss
  • K Bures
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a capillary electrophoresis method for routine determination of hemoglobins A2 and F.

Hemoglobin A2 (Hb A2) and hemoglobin F (Hb F) are important analytes in the diagnosis and follow up of Hb diseases. We evaluated a new capillary zone electrophoresis (CZE) kit for Hb A2 and Hb F measurements. The imprecision ranged from 3% to 6% for Hb A2 and Hb F at physiological and pathological concentrations. The method compared well with cation-exchange HPLC for Hb A2 and Hb F and with ani...

متن کامل

Capillary isoelectric focusing and high-performance cation-exchange chromatography compared for qualitative and quantitative analysis of hemoglobin variants.

We have developed two assays for complete analysis of hemoglobins (Hbs) in the field of hemoglobinopathies: a high-performance cation-exchange liquid chromatography (HPLC) assay on the weak cation-exchanger Poly Cat A and a two-step capillary isoelectric focusing (CIEF) assay on the neutral-coated capillary from Beckman in a narrow pH gradient. The resolution was satisfactory for both HPLC and ...

متن کامل

Chromatographic measurements of hemoglobin A2 in blood samples that contain sickle hemoglobin.

In the sickle cell syndromes, Hb A2 measurements aid in the differential diagnosis of sickle cell anemia from sickle-beta-thalassemia. The purpose of this study is to assess the Hb A2 levels in samples containing sickle hemoglobin (Hb S) by the use of an automated high performance liquid chromatography system (HPLC-Variant beta-thalassemia Short Program). The blood samples analyzed were from in...

متن کامل

Rapid analysis of hemoglobin variants by cation-exchange HPLC.

We investigated the use of a 3.5 x 0.46 cm HPLC column packed with 5-microns particles of porous (100 nm) silica coated with polyaspartic acid for hemoglobin analysis. A 13-min gradient was produced between two mobile phases. The method is capable of separating more than 35 commonly encountered hemoglobin variants within 12 min. Hemoglobin variants identified include Bart's, acetyl F, H, A1c, F...

متن کامل

HPLC retention time as a diagnostic tool for hemoglobin variants and hemoglobinopathies: a study of 60000 samples in a clinical diagnostic laboratory.

BACKGROUND Previous evaluations of HPLC as a tool for detection of hemoglobin variants have done so within newborn-screening programs and/or by use of stored samples. We describe a 32-month prospective study in a clinical diagnostic laboratory in which we evaluated the imprecision of HPLC retention times and determined the retention times for hemoglobin variants seen in a multiethnic setting. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 42 7  شماره 

صفحات  -

تاریخ انتشار 1996